VMAX Doc - clarification and typo fixes
Fixing formating in setup section for clarification and other minor typo fixes Change-Id: Ice0c38dc95a6a40f41ee77e453ec42376bb367d6 Closes-Bug: #1729258
This commit is contained in:
parent
c25be040fa
commit
4813583b6f
@ -111,6 +111,10 @@ VMAX drivers also support the following features:
|
||||
This means volumes added to any newly created storage groups will be
|
||||
compressed.
|
||||
|
||||
|
||||
VMAX Driver Integration
|
||||
~~~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
#. Install iSCSI Utilities (for iSCSI drivers only).
|
||||
|
||||
#. Download and configure the Cinder node as an iSCSI initiator.
|
||||
@ -163,7 +167,7 @@ VMAX drivers also support the following features:
|
||||
VMAX). See ``Unisphere for VMAX 8.4.0 Installation Guide`` at
|
||||
``support.emc.com``.
|
||||
|
||||
#. Configure Block Storage
|
||||
#. Configure Block Storage in cinder.conf
|
||||
|
||||
Add the following entries to ``/etc/cinder/cinder.conf``:
|
||||
|
||||
@ -189,6 +193,8 @@ VMAX drivers also support the following features:
|
||||
containing additional settings. Note that the file name is in the format
|
||||
``/etc/cinder/cinder_dell_emc_config_[confGroup].xml``.
|
||||
|
||||
#. Create Volume Types
|
||||
|
||||
Once the ``cinder.conf`` and EMC-specific configuration files have been
|
||||
created, :command:`openstack` commands need to be issued in order to
|
||||
create and associate OpenStack volume types with the declared
|
||||
@ -201,72 +207,61 @@ VMAX drivers also support the following features:
|
||||
There is also the option to assign a port group to a volume type by
|
||||
setting the ``storagetype:portgroupname`` extra specification.
|
||||
|
||||
``ServiceLevel``
|
||||
The Service Level manages the underlying storage to provide expected
|
||||
performance. Setting the ``ServiceLevel`` to ``NONE`` means that non-FAST
|
||||
managed storage groups will be created instead (storage groups not
|
||||
associated with any service level).
|
||||
.. note::
|
||||
|
||||
``Workload``
|
||||
When a workload type is added, the latency range is reduced due to the
|
||||
added information. Setting the ``Workload`` to ``NONE`` means the latency
|
||||
range will be the widest for its Service Level type. Please note that you
|
||||
cannot set a Workload without a Service Level.
|
||||
Run the command cinder get-pools --detail to query for the pool
|
||||
information. This should list all the available Service Level and Workload
|
||||
combinations available for the SRP as pools belonging to the same backend.
|
||||
You can create many volume types for different service level and workload
|
||||
types using the same backend.
|
||||
|
||||
.. note::
|
||||
``ServiceLevel``
|
||||
The Service Level manages the underlying storage to provide expected
|
||||
performance. Setting the ``ServiceLevel`` to ``NONE`` means that non-FAST
|
||||
managed storage groups will be created instead (storage groups not
|
||||
associated with any service level).
|
||||
|
||||
Run the command cinder get-pools --detail to query for the pool
|
||||
information. This should list all the available Service Level and Workload
|
||||
combinations available for the SRP as pools belonging to the same backend.
|
||||
You can create many volume types for different service level and workload
|
||||
types using the same backend.
|
||||
|
||||
``Port Groups``
|
||||
Port groups refer to VMAX port groups that have been pre-configured to
|
||||
expose volumes managed by this backend. Each supplied port group should
|
||||
have sufficient number and distribution of ports (across directors and
|
||||
switches) as to ensure adequate bandwidth and failure protection for the
|
||||
volume connections. PortGroups can contain one or more port groups of
|
||||
either iSCSI or FC ports. Make sure that any PortGroups provided contain
|
||||
either all FC or all iSCSI port groups (for a given back end), as
|
||||
appropriate for the configured driver (iSCSI or FC). Port groups can be
|
||||
assigned as an extra spec, or can be provided in the xml file.
|
||||
Port groups provided as the extra spec are selected first.
|
||||
|
||||
.. note::
|
||||
|
||||
Create as many volume types as the number of Service Level and Workload
|
||||
(available) combinations which you are going to use for provisioning
|
||||
volumes. The pool_name is the additional property which has to be set and
|
||||
is of the format: ``<ServiceLevel>+<Workload>+<SRP>+<Array ID>``. This
|
||||
can be obtained from the output of the ``cinder get-pools--detail``.
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
$ openstack volume type create VMAX_ISCI_SILVER_OLTP
|
||||
$ openstack volume type set --property volume_backend_name=ISCSI_backend \
|
||||
--property pool_name=Silver+OLTP+SRP_1+000197800123 \
|
||||
--property storagetype:portgroupname=OS-PG2 \
|
||||
VMAX_ ISCI_SILVER_OLTP
|
||||
$ openstack volume type create VMAX_FC_DIAMOND_DSS
|
||||
$ openstack volume type set --property volume_backend_name=FC_backend \
|
||||
--property pool_name=Diamond+DSS+SRP_1+000197800123 \
|
||||
--property port_group_name=OS-PG1 \
|
||||
VMAX_FC_DIAMOND_DSS
|
||||
``Workload``
|
||||
When a workload type is added, the latency range is reduced due to the
|
||||
added information. Setting the ``Workload`` to ``NONE`` means the latency
|
||||
range will be the widest for its Service Level type. Please note that you
|
||||
cannot set a Workload without a Service Level.
|
||||
|
||||
|
||||
By issuing these commands, the Block Storage volume type
|
||||
``VMAX_ISCSI_SILVER_OLTP`` is associated with the ``ISCSI_backend``, a Silver
|
||||
Service Level, and an OLTP workload.
|
||||
.. note::
|
||||
|
||||
The type ``VMAX_FC_DIAMOND_DSS`` is associated with the ``FC_backend``, a
|
||||
Diamond Service Level, and a DSS workload.
|
||||
It is possible to create as many volume types as the number of Service Level
|
||||
and Workload(available) combination for provisioning volumes. The pool_name
|
||||
is the additional property which has to be set and is of the format:
|
||||
``<ServiceLevel>+<Workload>+<SRP>+<Array ID>``.
|
||||
This can be obtained from the output of the ``cinder get-pools--detail``.
|
||||
|
||||
.. note::
|
||||
.. code-block:: console
|
||||
|
||||
VMAX Hybrid supports Optimized, Diamond, Platinum, Gold, Silver, Bronze,
|
||||
and NONE service levels. VMAX All Flash supports Diamond and NONE. Both
|
||||
support DSS_REP, DSS, OLTP_REP, OLTP, and NONE workloads.
|
||||
$ openstack volume type create VMAX_ISCSI_SILVER_OLTP
|
||||
$ openstack volume type set --property volume_backend_name=ISCSI_backend \
|
||||
--property pool_name=Silver+OLTP+SRP_1+000197800123 \
|
||||
--property storagetype:portgroupname=OS-PG2 \
|
||||
VMAX_ISCSI_SILVER_OLTP
|
||||
$ openstack volume type create VMAX_FC_DIAMOND_DSS
|
||||
$ openstack volume type set --property volume_backend_name=FC_backend \
|
||||
--property pool_name=Diamond+DSS+SRP_1+000197800123 \
|
||||
--property storagetype:portgroupname=OS-PG1 \
|
||||
VMAX_FC_DIAMOND_DSS
|
||||
|
||||
|
||||
By issuing these commands, the Block Storage volume type
|
||||
``VMAX_ISCSI_SILVER_OLTP`` is associated with the ``ISCSI_backend``, a Silver
|
||||
Service Level, and an OLTP workload.
|
||||
|
||||
The type ``VMAX_FC_DIAMOND_DSS`` is associated with the ``FC_backend``, a
|
||||
Diamond Service Level, and a DSS workload.
|
||||
|
||||
.. note::
|
||||
|
||||
VMAX Hybrid supports Optimized, Diamond, Platinum, Gold, Silver, Bronze,
|
||||
and NONE service levels. VMAX All Flash supports Diamond and NONE. Both
|
||||
support DSS_REP, DSS, OLTP_REP, OLTP, and NONE workloads.
|
||||
|
||||
#. Create an XML file
|
||||
|
||||
@ -276,53 +271,58 @@ Diamond Service Level, and a DSS workload.
|
||||
Add the following lines to the XML file:
|
||||
|
||||
|
||||
.. code-block:: xml
|
||||
.. code-block:: xml
|
||||
|
||||
<?xml version="1.0" encoding="UTF-8" ?>
|
||||
<EMC>
|
||||
<RestServerIp>1.1.1.1</RestServerIp>
|
||||
<RestServerPort>8443</RestServerPort>
|
||||
<RestUserName>smc</RestUserName>
|
||||
<RestPassword>smc</RestPassword>
|
||||
<PortGroups>
|
||||
<PortGroup>OS-PORTGROUP1-PG</PortGroup>
|
||||
<PortGroup>OS-PORTGROUP2-PG</PortGroup>
|
||||
</PortGroups>
|
||||
<Array>111111111111</Array>
|
||||
<SRP>SRP_1</SRP>
|
||||
<SSLVerify>/path/to/sslcert</SSLVerify>
|
||||
</EMC>
|
||||
<?xml version="1.0" encoding="UTF-8" ?>
|
||||
<EMC>
|
||||
<RestServerIp>1.1.1.1</RestServerIp>
|
||||
<RestServerPort>8443</RestServerPort>
|
||||
<RestUserName>smc</RestUserName>
|
||||
<RestPassword>smc</RestPassword>
|
||||
<PortGroups>
|
||||
<PortGroup>OS-PORTGROUP1-PG</PortGroup>
|
||||
<PortGroup>OS-PORTGROUP2-PG</PortGroup>
|
||||
</PortGroups>
|
||||
<Array>111111111111</Array>
|
||||
<SRP>SRP_1</SRP>
|
||||
<SSLVerify>/path/to/sslcert</SSLVerify>
|
||||
</EMC>
|
||||
|
||||
Where:
|
||||
Where:
|
||||
|
||||
``RestServerIp``
|
||||
IP address of the Unisphere server.
|
||||
``RestServerIp``
|
||||
IP address of the Unisphere server.
|
||||
|
||||
``RestServerPort``
|
||||
Port number of the Unisphere server.
|
||||
``RestServerPort``
|
||||
Port number of the Unisphere server.
|
||||
|
||||
``RestUserName`` and ``RestPassword``
|
||||
Credentials for the Unisphere server.
|
||||
``RestUserName`` and ``RestPassword``
|
||||
Credentials for the Unisphere server.
|
||||
|
||||
``PortGroups``
|
||||
Supplies the names of VMAX port groups that have been pre-configured to
|
||||
expose volumes managed by this array. Port groups can be supplied in the
|
||||
XML file, or can be specified as an extra spec on a volume type for more
|
||||
control. Please see above section on port groups. When a dynamic masking
|
||||
view is created by the VMAX driver, if there is no port group specified
|
||||
as an extra specification, the port group is chosen randomly from the
|
||||
PortGroup list, to evenly distribute load across the set of groups
|
||||
provided.
|
||||
``PortGroups``
|
||||
Supplies the names of VMAX port groups that have been pre-configured to
|
||||
expose volumes managed by this array. Port groups can be supplied in the
|
||||
XML file, or can be specified as an extra spec on a volume type for more
|
||||
control. Please see above section on port groups. When a dynamic masking
|
||||
view is created by the VMAX driver, if there is no port group specified
|
||||
as an extra specification, the port group is chosen randomly from the
|
||||
PortGroup list, to evenly distribute load across the set of groups
|
||||
provided.
|
||||
|
||||
``Array``
|
||||
Unique VMAX array serial number.
|
||||
.. note::
|
||||
|
||||
``SRP``
|
||||
The name of the storage resource pool for the given array.
|
||||
There is also the option to assign a port group to a volume type by
|
||||
setting the ``storagetype:portgroupname`` extra specification.
|
||||
|
||||
``SSLVerify``
|
||||
The path to the ``ca_cert.pem`` file of the Unisphere instance below, or
|
||||
``True`` if the SSL cert has been added to the bundle - see ``SSL support``.
|
||||
``Array``
|
||||
Unique VMAX array serial number.
|
||||
|
||||
``SRP``
|
||||
The name of the storage resource pool for the given array.
|
||||
|
||||
``SSLVerify``
|
||||
The path to the ``ca_cert.pem`` file of the Unisphere instance below, or
|
||||
``True`` if the SSL cert has been added to the bundle - see ``SSL support``.
|
||||
|
||||
|
||||
Upgrading from SMI-S based driver to RESTAPI based driver
|
||||
@ -456,6 +456,10 @@ Masking views are dynamically created by the VMAX FC and iSCSI drivers using
|
||||
the following naming conventions. ``[protocol]`` is either ``I`` for volumes
|
||||
attached over iSCSI or ``F`` for volumes attached over Fiber Channel.
|
||||
|
||||
.. code-block:: text
|
||||
|
||||
OS-[shortHostName]-[protocol]-[portgroup_name]-MV
|
||||
|
||||
Initiator group names
|
||||
---------------------
|
||||
|
||||
@ -530,7 +534,7 @@ if multiple concurrent provisioning requests are issued then ``retries``
|
||||
should be increased so calls will not timeout prematurely.
|
||||
|
||||
In the example below, the driver checks every 3 seconds for the status of the
|
||||
job. It will continue checking for 150 retries before it times out.
|
||||
job. It will continue checking for 200 retries before it times out.
|
||||
|
||||
Add the following lines to the VMAX backend in the cinder.conf:
|
||||
|
||||
@ -547,10 +551,10 @@ Add the following lines to the VMAX backend in the cinder.conf:
|
||||
QoS (Quality of Service) support
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
Quality of service (QOS) has traditionally been associated with network
|
||||
Quality of service (QoS) has traditionally been associated with network
|
||||
bandwidth usage. Network administrators set limitations on certain networks
|
||||
in terms of bandwidth usage for clients. This enables them to provide a
|
||||
tiered level of service based on cost. The Nova/cinder QOS offer similar
|
||||
tiered level of service based on cost. The Nova/cinder QoS offer similar
|
||||
functionality based on volume type setting limits on host storage bandwidth
|
||||
per service offering. Each volume type is tied to specific QoS attributes
|
||||
some of which are unique to each storage vendor. In the hypervisor, the QoS
|
||||
@ -709,14 +713,55 @@ above.
|
||||
Libvirt includes an extra xml flag within the <disk> section called iotune
|
||||
that is responsible for rate limitation. To confirm that, first get the
|
||||
``OS-EXT-SRV-ATTR:instance_name`` value of the server instance
|
||||
i.e. instance-00000005. We then run the following command using the
|
||||
i.e. instance-00000003.
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
$ openstack server show <serverid>
|
||||
|
||||
+-------------------------------------+-----------------------------------------------------------------+
|
||||
| Field | Value |
|
||||
+-------------------------------------+-----------------------------------------------------------------+
|
||||
| OS-DCF:diskConfig | AUTO |
|
||||
| OS-EXT-AZ:availability_zone | nova |
|
||||
| OS-EXT-SRV-ATTR:host | myhost |
|
||||
| OS-EXT-SRV-ATTR:hypervisor_hostname | myhost |
|
||||
| OS-EXT-SRV-ATTR:instance_name | instance-00000003 |
|
||||
| OS-EXT-STS:power_state | Running |
|
||||
| OS-EXT-STS:task_state | None |
|
||||
| OS-EXT-STS:vm_state | active |
|
||||
| OS-SRV-USG:launched_at | 2017-11-02T08:15:42.000000 |
|
||||
| OS-SRV-USG:terminated_at | None |
|
||||
| accessIPv4 | |
|
||||
| accessIPv6 | |
|
||||
| addresses | private=fd21:99c2:73f3:0:f816:3eff:febe:30ed, 10.0.0.3 |
|
||||
| config_drive | |
|
||||
| created | 2017-11-02T08:15:34Z |
|
||||
| flavor | m1.tiny (1) |
|
||||
| hostId | e7b8312581f9fbb8508587d45c0b6fb4dc86102c632ed1f3a6a49d42 |
|
||||
| id | 0ef0ff4c-dbda-4dc7-b8ed-45d2fc2f31db |
|
||||
| image | cirros-0.3.5-x86_64-disk (b7c220f5-2408-4296-9e58-fc5a41cb7e9d) |
|
||||
| key_name | myhostname |
|
||||
| name | myhosthame |
|
||||
| progress | 0 |
|
||||
| project_id | bae4b97a0d8b42c28a5add483981e5db |
|
||||
| properties | |
|
||||
| security_groups | name='default' |
|
||||
| status | ACTIVE |
|
||||
| updated | 2017-11-02T08:15:42Z |
|
||||
| user_id | 7bccf456740546799a7e20457f13c38b |
|
||||
| volumes_attached | |
|
||||
+-------------------------------------+-----------------------------------------------------------------+
|
||||
|
||||
We then run the following command using the
|
||||
``OS-EXT-SRV-ATTR:instance_name`` retrieved above.
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
$ virsh dumpxml instance-00000005 | grep -1 "total_bytes_sec\|total_iops_sec"
|
||||
$ virsh dumpxml instance-00000003 | grep -1 "total_bytes_sec\|total_iops_sec"
|
||||
|
||||
The outcome is shown below
|
||||
The output of the command contains the xml below. It is found between the
|
||||
``<disk>`` start and end tag.
|
||||
|
||||
.. code-block:: xml
|
||||
|
||||
@ -928,9 +973,10 @@ On Compute (nova) node, add the following flag in the ``[libvirt]`` section of
|
||||
|
||||
.. code-block:: ini
|
||||
|
||||
iscsi_use_multipath = True
|
||||
volume_use_multipath = True
|
||||
|
||||
On cinder controller node, set the multipath flag to true in
|
||||
On cinder controller node, iSCSI MPIO can be set globally in the
|
||||
[DEFAULT] section or set individually in the VMAX backend stanza in
|
||||
:file:`/etc/cinder/cinder.conf`:
|
||||
|
||||
.. code-block:: ini
|
||||
@ -969,40 +1015,6 @@ Verify you have multiple initiators available on the compute node for I/O
|
||||
vda
|
||||
|
||||
|
||||
Workload Planner (WLP)
|
||||
~~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
VMAX Hybrid allows you to manage application storage by using Service Level
|
||||
(SL) using policy based automation. The VMAX Hybrid comes with
|
||||
up to 6 SL policies defined. Each has a
|
||||
set of workload characteristics that determine the drive types and mixes
|
||||
which will be used for the SL. All storage in the VMAX Array is virtually
|
||||
provisioned, and all of the pools are created in containers called Storage
|
||||
Resource Pools (SRP). Typically there is only one SRP, however there can be
|
||||
more. Therefore, it is the same pool we will provision to but we can provide
|
||||
different SLO/Workload combinations.
|
||||
|
||||
The SL capacity is retrieved by interfacing with Unisphere Workload Planner
|
||||
(WLP). If you do not set up this relationship then the capacity retrieved is
|
||||
that of the entire SRP. This can cause issues as it can never be an accurate
|
||||
representation of what storage is available for any given SL and Workload
|
||||
combination.
|
||||
|
||||
Enabling WLP on Unisphere
|
||||
-------------------------
|
||||
|
||||
#. To enable WLP on Unisphere, click on the
|
||||
:menuselection:`array-->Performance-->Settings`.
|
||||
#. Set both the :guilabel:`Real Time` and the :guilabel:`Root Cause Analysis`.
|
||||
#. Click :guilabel:`Register`.
|
||||
|
||||
.. note::
|
||||
|
||||
This should be set up ahead of time (allowing for several hours of data
|
||||
collection), so that the Unisphere for VMAX Performance Analyzer can
|
||||
collect rated metrics for each of the supported element types.
|
||||
|
||||
|
||||
All Flash compression support
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
@ -1040,18 +1052,7 @@ Use case 1 - Compression disabled create, attach, detach, and delete volume
|
||||
it should also be deleted.
|
||||
|
||||
|
||||
Use case 2 - Compression disabled create, delete snapshot and delete volume
|
||||
---------------------------------------------------------------------------
|
||||
|
||||
#. Repeat steps 1-5 of Use case 1.
|
||||
#. Create a snapshot. The volume should now exist in
|
||||
``OS-<srp>-<servicelevel>-<workload>-CD-SG``.
|
||||
#. Delete the snapshot. The volume should be removed from
|
||||
``OS-<srp>-<servicelevel>-<workload>-CD-SG``.
|
||||
#. Delete the volume. If this volume is the last volume in
|
||||
``OS-<srp>-<servicelevel>-<workload>-CD-SG``, it should also be deleted.
|
||||
|
||||
Use case 3 - Retype from compression disabled to compression enabled
|
||||
Use case 2 - Retype from compression disabled to compression enabled
|
||||
--------------------------------------------------------------------
|
||||
|
||||
#. Repeat steps 1-4 of Use case 1.
|
||||
@ -1108,8 +1109,12 @@ Configure the source and target arrays
|
||||
value pairs.
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
|
||||
[DEFAULT]
|
||||
enabled_backends = VMAX_FC_REPLICATION
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
[VMAX_FC_REPLICATION]
|
||||
volume_driver = cinder.volume.drivers.dell_emc.vmax_fc.VMAXFCDriver
|
||||
cinder_dell_emc_config_file = /etc/cinder/cinder_dell_emc_config_VMAX_FC_REPLICATION.xml
|
||||
@ -1163,7 +1168,7 @@ Configure the source and target arrays
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
$ openstack volume type set --property replication_enabled = "<is> True" \
|
||||
$ openstack volume type set --property replication_enabled="<is> True" \
|
||||
VMAX_FC_REPLICATION
|
||||
|
||||
|
||||
@ -1204,16 +1209,14 @@ host command to failover to the configured target:
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
$ cinder failover-host cinder_host@VMAX_FC_REPLICATION#Diamond+SRP_1+000192800111
|
||||
$ cinder failover-host cinder_host@VMAX_FC_REPLICATION
|
||||
|
||||
If the primary array becomes available again, you can initiate a failback
|
||||
using the same command and specifying ``--backend_id default``:
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
$ cinder failover-host \
|
||||
cinder_host@VMAX_FC_REPLICATION#Diamond+SRP_1+000192800111 \
|
||||
--backend_id default
|
||||
$ cinder failover-host cinder_host@VMAX_FC_REPLICATION --backend_id default
|
||||
|
||||
|
||||
Volume retype - storage assisted volume migration
|
||||
@ -1309,7 +1312,7 @@ Operations
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
cinder --os-volume-api-version 3.11 group-type-key GROUP_TYPE set consistent_group_snapshot_enabled= "<is> True"
|
||||
cinder --os-volume-api-version 3.11 group-type-key GROUP_TYPE set consistent_group_snapshot_enabled="<is> True"
|
||||
|
||||