Dell EMC SC: dell-storagecenter-driver docs updated
Document has been updated to include direct connect support. The Dell EMC SC driver can be configured to point at a Storage Center directly rather than through a DSM aggregator. This addresses minimum requirements and limitation. Change-Id: I0a0095235685c8f6dc6d9cd88b27d454641da387
This commit is contained in:
parent
9e283258fe
commit
4cfdbc3f5f
@ -5,11 +5,22 @@ Dell EMC SC Series Fibre Channel and iSCSI drivers
|
|||||||
The Dell EMC Storage Center volume driver interacts with configured Storage
|
The Dell EMC Storage Center volume driver interacts with configured Storage
|
||||||
Center arrays.
|
Center arrays.
|
||||||
|
|
||||||
The Dell EMC Storage Center driver manages Storage Center arrays through
|
The Dell EMC Storage Center driver manages a Storage Center array via the
|
||||||
the Dell EMC Storage Manager (DSM). DSM connection settings and Storage
|
Dell EMC Storage Manager (DSM) Data Collector or by directly connecting to
|
||||||
Center options are defined in the ``cinder.conf`` file.
|
the Storage Center at the cost of replication and Live Volume functionality.
|
||||||
|
Also note that the directly connecting to the Storage Center is only
|
||||||
|
supported with Storage Center OS 7.1.1 or later. Any version of Storage
|
||||||
|
Center OS supported by DSM is supported if connecting via the Data
|
||||||
|
Collector.
|
||||||
|
|
||||||
Prerequisite: Dell EMC Storage Manager 2015 R1 or later must be used.
|
Driver configuration settings and Storage Center options are defined in the
|
||||||
|
``cinder.conf`` file.
|
||||||
|
|
||||||
|
Prerequisites:
|
||||||
|
|
||||||
|
- Storage Center OS version 7.1.1 or later and OpenStack Ocata or later
|
||||||
|
must be used if connecting directly to the Storage Center.
|
||||||
|
- Dell EMC Storage Manager 2015 R1 or later if connecting through DSM.
|
||||||
|
|
||||||
Supported operations
|
Supported operations
|
||||||
~~~~~~~~~~~~~~~~~~~~
|
~~~~~~~~~~~~~~~~~~~~
|
||||||
@ -27,8 +38,9 @@ volume operations:
|
|||||||
- Create, delete, list and update a consistency group.
|
- Create, delete, list and update a consistency group.
|
||||||
- Create, delete, and list consistency group snapshots.
|
- Create, delete, and list consistency group snapshots.
|
||||||
- Manage an existing volume.
|
- Manage an existing volume.
|
||||||
- Failover-host for replicated back ends.
|
- Replication (Requires DSM.)
|
||||||
- Create a replication using Live Volume.
|
- Failover-host for replicated back ends. (Requires DSM.)
|
||||||
|
- Create a replication using Live Volume. (Requires DSM.)
|
||||||
|
|
||||||
Extra spec options
|
Extra spec options
|
||||||
~~~~~~~~~~~~~~~~~~
|
~~~~~~~~~~~~~~~~~~
|
||||||
@ -36,7 +48,7 @@ Extra spec options
|
|||||||
Volume type extra specs can be used to enable a variety of Dell EMC Storage
|
Volume type extra specs can be used to enable a variety of Dell EMC Storage
|
||||||
Center options. Selecting Storage Profiles, Replay Profiles, enabling
|
Center options. Selecting Storage Profiles, Replay Profiles, enabling
|
||||||
replication, replication options including Live Volume and Active Replay
|
replication, replication options including Live Volume and Active Replay
|
||||||
replication.
|
replication. (Replication options are available when connected via DSM.)
|
||||||
|
|
||||||
Storage Profiles control how Storage Center manages volume data. For a
|
Storage Profiles control how Storage Center manages volume data. For a
|
||||||
given volume, the selected Storage Profile dictates which disk tier
|
given volume, the selected Storage Profile dictates which disk tier
|
||||||
@ -171,7 +183,7 @@ Use the following instructions to update the configuration file for iSCSI:
|
|||||||
volume_backend_name = delliscsi
|
volume_backend_name = delliscsi
|
||||||
# The iSCSI driver to load
|
# The iSCSI driver to load
|
||||||
volume_driver = cinder.volume.drivers.dell_emc.sc.storagecenter_iscsi.SCISCSIDriver
|
volume_driver = cinder.volume.drivers.dell_emc.sc.storagecenter_iscsi.SCISCSIDriver
|
||||||
# IP address of DSM
|
# IP address of the DSM or the Storage Center if attaching directly.
|
||||||
san_ip = 172.23.8.101
|
san_ip = 172.23.8.101
|
||||||
# DSM user name
|
# DSM user name
|
||||||
san_login = Admin
|
san_login = Admin
|
||||||
@ -206,7 +218,7 @@ channel:
|
|||||||
# The FC driver to load
|
# The FC driver to load
|
||||||
volume_driver = cinder.volume.drivers.dell_emc.sc.storagecenter_fc.SCFCDriver
|
volume_driver = cinder.volume.drivers.dell_emc.sc.storagecenter_fc.SCFCDriver
|
||||||
|
|
||||||
# IP address of the DSM
|
# IP address of the DSM or the Storage Center if attaching directly.
|
||||||
san_ip = 172.23.8.101
|
san_ip = 172.23.8.101
|
||||||
# DSM user name
|
# DSM user name
|
||||||
san_login = Admin
|
san_login = Admin
|
||||||
@ -251,6 +263,8 @@ to use the secondary. It will continue to use the secondary until the volume
|
|||||||
service is restarted or the secondary fails at which point it will attempt to
|
service is restarted or the secondary fails at which point it will attempt to
|
||||||
use the primary.
|
use the primary.
|
||||||
|
|
||||||
|
Note: Requires two DSM Data Collectors.
|
||||||
|
|
||||||
Replication configuration
|
Replication configuration
|
||||||
~~~~~~~~~~~~~~~~~~~~~~~~~
|
~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||||
|
|
||||||
@ -271,6 +285,10 @@ slow things down, however.
|
|||||||
A volume is only replicated if the volume is of a volume-type that has
|
A volume is only replicated if the volume is of a volume-type that has
|
||||||
the extra spec ``replication_enabled`` set to ``<is> True``.
|
the extra spec ``replication_enabled`` set to ``<is> True``.
|
||||||
|
|
||||||
|
Warning: replication_device requires DSM. If this is on a backend that
|
||||||
|
is directly connected to the Storage Center the driver will not load
|
||||||
|
as it is unable to meet the replication requirement.
|
||||||
|
|
||||||
Replication notes
|
Replication notes
|
||||||
~~~~~~~~~~~~~~~~~
|
~~~~~~~~~~~~~~~~~
|
||||||
|
|
||||||
@ -314,7 +332,7 @@ This option allows one to set a default Server OS type to use when creating
|
|||||||
a server definition on the Dell EMC Storage Center.
|
a server definition on the Dell EMC Storage Center.
|
||||||
|
|
||||||
When attaching a volume to a node the Dell EMC Storage Center driver creates a
|
When attaching a volume to a node the Dell EMC Storage Center driver creates a
|
||||||
server definition on the storage array. This defition includes a Server OS
|
server definition on the storage array. This definition includes a Server OS
|
||||||
type. The type used by the Dell EMC Storage Center cinder driver is
|
type. The type used by the Dell EMC Storage Center cinder driver is
|
||||||
"Red Hat Linux 6.x". This is a modern operating system definition that supports
|
"Red Hat Linux 6.x". This is a modern operating system definition that supports
|
||||||
all the features of an OpenStack node.
|
all the features of an OpenStack node.
|
||||||
|
Loading…
x
Reference in New Issue
Block a user