Huawei volume driver
====================
Huawei volume driver can be used to provide functions such as the logical
volume and snapshot for virtual machines (VMs) in the OpenStack Block Storage
driver that supports iSCSI and Fibre Channel protocols.
Version mappings
~~~~~~~~~~~~~~~~
The following table describes the version mappings among the Block Storage
driver, Huawei storage system and OpenStack:
.. list-table:: **Version mappings among the Block Storage driver and Huawei
storage system**
:widths: 30 35
:header-rows: 1
* - Description
- Storage System Version
* - Create, delete, expand, attach, detach, manage and unmanage volumes
Create volumes with assigned storage pools
Create volumes with assigned disk types
Create, delete and update a consistency group
Copy an image to a volume
Copy a volume to an image
Auto Zoning
SmartThin
Volume Migration
Replication V2.1
Create, delete, manage, unmanage and backup snapshots
Create and delete a cgsnapshot
- OceanStor T series V2R2 C00/C20/C30
OceanStor V3 V3R1C10/C20 V3R2C10 V3R3C00/C10/C20
OceanStor 2200V3 V300R005C00
OceanStor 2600V3 V300R005C00
OceanStor 18500/18800 V1R1C00/C20/C30 V3R3C00
OceanStor Dorado V300R001C00
OceanStor V3 V300R006C00
OceanStor 2200V3 V300R006C00
OceanStor 2600V3 V300R006C00
* - Clone a volume
Create volume from snapshot
Retype
SmartQoS
SmartTier
SmartCache
Thick
- OceanStor T series V2R2 C00/C20/C30
OceanStor V3 V3R1C10/C20 V3R2C10 V3R3C00/C10/C20
OceanStor 2200V3 V300R005C00
OceanStor 2600V3 V300R005C00
OceanStor 18500/18800V1R1C00/C20/C30
OceanStor V3 V300R006C00
OceanStor 2200V3 V300R006C00
OceanStor 2600V3 V300R006C00
* - SmartPartition
- OceanStor T series V2R2 C00/C20/C30
OceanStor V3 V3R1C10/C20 V3R2C10 V3R3C00/C10/C20
OceanStor 2600V3 V300R005C00
OceanStor 18500/18800V1R1C00/C20/C30
OceanStor V3 V300R006C00
OceanStor 2600V3 V300R006C00
* - Hypermetro
Hypermetro consistency group
- OceanStor V3 V3R3C00/C10/C20
OceanStor 2600V3 V3R5C00
OceanStor 18500/18800 V3R3C00
OceanStor Dorado V300R001C00
OceanStor V3 V300R006C00
OceanStor 2600V3 V300R006C00
Volume driver configuration
~~~~~~~~~~~~~~~~~~~~~~~~~~~
This section describes how to configure the Huawei volume driver for either
iSCSI storage or Fibre Channel storage.
**Pre-requisites**
When creating a volume from image, install the ``multipath`` tool and add the
following configuration keys in the ``[DEFAULT]`` configuration group of
the ``/etc/cinder/cinder.conf`` file:
.. code-block:: ini
use_multipath_for_image_xfer = True
enforce_multipath_for_image_xfer = True
To configure the volume driver, follow the steps below:
#. In ``/etc/cinder``, create a Huawei-customized driver configuration file.
The file format is XML.
#. Change the name of the driver configuration file based on the site
requirements, for example, ``cinder_huawei_conf.xml``.
#. Configure parameters in the driver configuration file.
Each product has its own value for the ``Product`` parameter under the
``Storage`` xml block. The full xml file with the appropriate ``Product``
parameter is as below:
.. code-block:: xml
PRODUCT
PROTOCOL
xxxxxxxx
xxxxxxxx
https://x.x.x.x:8088/deviceManager/rest/
xxx
xxx
xxx
x.x.x.x
The corresponding ``Product`` values for each product are as below:
* **For T series V2**
.. code-block:: xml
TV2
* **For V3**
.. code-block:: xml
V3
* **For OceanStor 18000 series**
.. code-block:: xml
18000
* **For OceanStor Dorado series**
.. code-block:: xml
Dorado
The ``Protocol`` value to be used is ``iSCSI`` for iSCSI and ``FC`` for
Fibre Channel as shown below:
.. code-block:: xml
# For iSCSI
iSCSI
# For Fibre channel
FC
.. note::
For details about the parameters in the configuration file, see the
`Configuration file parameters`_ section.
#. Configure the ``cinder.conf`` file.
In the ``[default]`` block of ``/etc/cinder/cinder.conf``,
enable the ``VOLUME_BACKEND``:
.. code-block:: ini
enabled_backends = VOLUME_BACKEND
Add a new block ``[VOLUME_BACKEND]``, and add the following contents:
.. code-block:: ini
[VOLUME_BACKEND]
volume_driver = VOLUME_DRIVER
cinder_huawei_conf_file = /etc/cinder/cinder_huawei_conf.xml
volume_backend_name = Huawei_Storage
* ``volume_driver`` indicates the loaded driver.
* ``cinder_huawei_conf_file`` indicates the specified Huawei-customized
configuration file.
* ``volume_backend_name`` indicates the name of the backend.
Add information about remote devices in ``/etc/cinder/cinder.conf``
in target backend block for ``Hypermetro``.
.. code-block:: ini
[VOLUME_BACKEND]
volume_driver = VOLUME_DRIVER
cinder_huawei_conf_file = /etc/cinder/cinder_huawei_conf.xml
volume_backend_name = Huawei_Storage
metro_san_user = xxx
metro_san_password = xxx
metro_domain_name = xxx
metro_san_address = https://x.x.x.x:8088/deviceManager/rest/
metro_storage_pools = xxx
Add information about remote devices in ``/etc/cinder/cinder.conf``
in target backend block for ``Replication``.
.. code-block:: ini
[VOLUME_BACKEND]
volume_driver = VOLUME_DRIVER
cinder_huawei_conf_file = /etc/cinder/cinder_huawei_conf.xml
volume_backend_name = Huawei_Storage
replication_device =
backend_id: xxx,
storage_pool :xxx,
san_address: https://x.x.x.x:8088/deviceManager/rest/,
san_user: xxx,
san_password: xxx,
iscsi_default_target_ip: x.x.x.x
.. note::
By default, the value for ``Hypermetro`` and ``Replication`` is
``None``. For details about the parameters in the configuration file,
see the `Configuration file parameters`_ section.
The ``volume-driver`` value for every product is as below:
.. code-block:: ini
# For iSCSI
volume_driver = cinder.volume.drivers.huawei.huawei_driver.HuaweiISCSIDriver
# For FC
volume_driver = cinder.volume.drivers.huawei.huawei_driver.HuaweiFCDriver
#. Run the :command:`service cinder-volume restart` command to restart the
Block Storage service.
Configuring iSCSI Multipathing
------------------------------
To configure iSCSI Multipathing, follow the steps below:
#. Add the port group settings in the Huawei-customized driver configuration
file and configure the port group name needed by an initiator.
.. code-block:: xml
x.x.x.x
#. Enable the multipathing switch of the Compute service module.
Add ``volume_use_multipath = True`` in ``[libvirt]`` of
``/etc/nova/nova.conf``.
#. Run the :command:`service nova-compute restart` command to restart the
``nova-compute`` service.
Configuring FC Multipathing
------------------------------
To configure FC Multipathing, follow the steps below:
#. Enable the multipathing switch of the Compute service module.
Add ``volume_use_multipath = True`` in ``[libvirt]`` of
``/etc/nova/nova.conf``.
#. Run the :command:`service nova-compute restart` command to restart the
``nova-compute`` service.
Configuring CHAP and ALUA
-------------------------
On a public network, any application server whose IP address resides on the
same network segment as that of the storage systems iSCSI host port can access
the storage system and perform read and write operations in it. This poses
risks to the data security of the storage system. To ensure the storage
systems access security, you can configure ``CHAP`` authentication to control
application servers access to the storage system.
Adjust the driver configuration file as follows:
.. code-block:: xml
``ALUA`` indicates a multipathing mode. 0 indicates that ``ALUA`` is disabled.
1 indicates that ``ALUA`` is enabled. ``CHAPinfo`` indicates the user name and
password authenticated by ``CHAP``. The format is ``mmuser; mm-user@storage``.
The user name and password are separated by semicolons (``;``).
Configuring multiple storage
----------------------------
Multiple storage systems configuration example:
.. code-block:: ini
enabled_backends = v3_fc, 18000_fc
[v3_fc]
volume_driver = cinder.volume.drivers.huawei.huawei_driver.HuaweiFCDriver
cinder_huawei_conf_file = /etc/cinder/cinder_huawei_conf_v3_fc.xml
volume_backend_name = huawei_v3_fc
[18000_fc]
volume_driver = cinder.volume.drivers.huawei.huawei_driver.HuaweiFCDriver
cinder_huawei_conf_file = /etc/cinder/cinder_huawei_conf_18000_fc.xml
volume_backend_name = huawei_18000_fc
Configuration file parameters
-----------------------------
This section describes mandatory and optional configuration file parameters
of the Huawei volume driver.
.. list-table:: **Mandatory parameters**
:widths: 10 10 50 10
:header-rows: 1
* - Parameter
- Default value
- Description
- Applicable to
* - Product
- ``-``
- Type of a storage product. Possible values are ``TV2``, ``18000`` and
``V3``.
- All
* - Protocol
- ``-``
- Type of a connection protocol. The possible value is either ``'iSCSI'``
or ``'FC'``.
- All
* - RestURL
- ``-``
- Access address of the REST interface,
``https://x.x.x.x/devicemanager/rest/``. The value ``x.x.x.x`` indicates
the management IP address. OceanStor 18000 uses the preceding setting,
and V2 and V3 requires you to add port number ``8088``, for example,
``https://x.x.x.x:8088/deviceManager/rest/``. If you need to configure
multiple RestURL, separate them by semicolons (;).
- All
* - UserName
- ``-``
- User name of a storage administrator.
- All
* - UserPassword
- ``-``
- Password of a storage administrator.
- All
* - StoragePool
- ``-``
- Name of a storage pool to be used. If you need to configure multiple
storage pools, separate them by semicolons (``;``).
- All
.. note::
The value of ``StoragePool`` cannot contain Chinese characters.
.. list-table:: **Optional parameters**
:widths: 20 10 50 15
:header-rows: 1
* - Parameter
- Default value
- Description
- Applicable to
* - LUNType
- Thick
- Type of the LUNs to be created. The value can be ``Thick`` or ``Thin``. Dorado series only support ``Thin`` LUNs.
- All
* - WriteType
- 1
- Cache write type, possible values are: ``1`` (write back), ``2``
(write through), and ``3`` (mandatory write back).
- All
* - LUNcopyWaitInterval
- 5
- After LUN copy is enabled, the plug-in frequently queries the copy
progress. You can set a value to specify the query interval.
- All
* - Timeout
- 432000
- Timeout interval for waiting LUN copy of a storage device to complete.
The unit is second.
- All
* - Initiator Name
- ``-``
- Name of a compute node initiator.
- All
* - Initiator TargetIP
- ``-``
- IP address of the iSCSI port provided for compute nodes.
- All
* - Initiator TargetPortGroup
- ``-``
- IP address of the iSCSI target port that is provided for compute
nodes.
- All
* - DefaultTargetIP
- ``-``
- Default IP address of the iSCSI target port that is provided for
compute nodes.
- All
* - OSType
- Linux
- Operating system of the Nova compute node's host.
- All
* - HostIP
- ``-``
- IP address of the Nova compute node's host.
- All
* - metro_san_user
- ``-``
- User name of a storage administrator of hypermetro remote device.
- V3R3/2600 V3R5/18000 V3R3
* - metro_san_password
- ``-``
- Password of a storage administrator of hypermetro remote device.
- V3R3/2600 V3R5/18000 V3R3
* - metro_domain_name
- ``-``
- Hypermetro domain name configured on ISM.
- V3R3/2600 V3R5/18000 V3R3
* - metro_san_address
- ``-``
- Access address of the REST interface, https://x.x.x.x/devicemanager/rest/. The value x.x.x.x indicates the management IP address.
- V3R3/2600 V3R5/18000 V3R3
* - metro_storage_pools
- ``-``
- Remote storage pool for hypermetro.
- V3R3/2600 V3R5/18000 V3R3
* - backend_id
- ``-``
- Target device ID.
- All
* - storage_pool
- ``-``
- Pool name of target backend when failover for replication.
- All
* - san_address
- ``-``
- Access address of the REST interface, https://x.x.x.x/devicemanager/rest/. The value x.x.x.x indicates the management IP address.
- All
* - san_user
- ``-``
- User name of a storage administrator of replication remote device.
- All
* - san_password
- ``-``
- Password of a storage administrator of replication remote device.
- All
* - iscsi_default_target_ip
- ``-``
- Remote transacton port IP.
- All
.. important::
The ``Initiator Name``, ``Initiator TargetIP``, and
``Initiator TargetPortGroup`` are ``ISCSI`` parameters and therefore not
applicable to ``FC``.
The following are the Huawei driver specific options that may be set in
`cinder.conf`:
.. config-table::
:config-target: Huawei
cinder.volume.drivers.huawei.huawei_driver