cinder/doc/source/configuration/tables/cinder-storwize.rst
Jay S. Bryant 0395353c4b Move config-reference to configuration
It was discovered today that the 'config-reference' directory
was supposed to have been renamed to 'configuration'.  The doc
team was expecting it to be at that location so that they could
automatically link to it from contributor/index.html .

This patch just moves the directory.  I am going to be submitting
a subsequent patch that properly sets out the framework for the
additional directories so that we don't have addition problems
in the future.

Change-Id: I6729aaf4593a0b089277f6d7d0aa50fee3ca340f
2017-07-18 13:10:25 -05:00

65 lines
3.3 KiB
ReStructuredText

..
Warning: Do not edit this file. It is automatically generated from the
software project's code and your changes will be overwritten.
The tool to generate this file lives in openstack-doc-tools repository.
Please make any changes needed in the code, then run the
autogenerate-config-doc tool from the openstack-doc-tools repository, or
ask for help on the documentation mailing list, IRC channel or meeting.
.. _cinder-storwize:
.. list-table:: Description of IBM Storwise driver configuration options
:header-rows: 1
:class: config-ref-table
* - Configuration option = Default value
- Description
* - **[DEFAULT]**
-
* - ``san_ip`` =
- (String) IP address of SAN controller
* - ``san_login`` = ``admin``
- (String) Username for SAN controller
* - ``san_password`` =
- (String) Password for SAN controller
* - ``san_private_key`` =
- (String) Filename of private key to use for SSH authentication
* - ``san_ssh_port`` = ``22``
- (Port number) SSH port to use with SAN
* - ``storwize_san_secondary_ip`` = ``None``
- (String) Specifies secondary management IP or hostname to be used if san_ip is invalid or becomes inaccessible.
* - ``storwize_svc_allow_tenant_qos`` = ``False``
- (Boolean) Allow tenants to specify QOS on create
* - ``storwize_svc_flashcopy_rate`` = ``50``
- (Integer) Specifies the Storwize FlashCopy copy rate to be used when creating a full volume copy. The default is rate is 50, and the valid rates are 1-100.
* - ``storwize_svc_flashcopy_timeout`` = ``120``
- (Integer) Maximum number of seconds to wait for FlashCopy to be prepared.
* - ``storwize_svc_iscsi_chap_enabled`` = ``True``
- (Boolean) Configure CHAP authentication for iSCSI connections (Default: Enabled)
* - ``storwize_svc_multihostmap_enabled`` = ``True``
- (Boolean) DEPRECATED: This option no longer has any affect. It is deprecated and will be removed in the next release.
* - ``storwize_svc_multipath_enabled`` = ``False``
- (Boolean) Connect with multipath (FC only; iSCSI multipath is controlled by Nova)
* - ``storwize_svc_stretched_cluster_partner`` = ``None``
- (String) If operating in stretched cluster mode, specify the name of the pool in which mirrored copies are stored.Example: "pool2"
* - ``storwize_svc_vol_autoexpand`` = ``True``
- (Boolean) Storage system autoexpand parameter for volumes (True/False)
* - ``storwize_svc_vol_compression`` = ``False``
- (Boolean) Storage system compression option for volumes
* - ``storwize_svc_vol_easytier`` = ``True``
- (Boolean) Enable Easy Tier for volumes
* - ``storwize_svc_vol_grainsize`` = ``256``
- (Integer) Storage system grain size parameter for volumes (32/64/128/256)
* - ``storwize_svc_vol_iogrp`` = ``0``
- (Integer) The I/O group in which to allocate volumes
* - ``storwize_svc_vol_nofmtdisk`` = ``False``
- (Boolean) Specifies that the volume not be formatted during creation.
* - ``storwize_svc_vol_rsize`` = ``2``
- (Integer) Storage system space-efficiency parameter for volumes (percentage)
* - ``storwize_svc_vol_warning`` = ``0``
- (Integer) Storage system threshold for volume capacity warnings (percentage)
* - ``storwize_svc_volpool_name`` = ``volpool``
- (List) Comma separated list of storage system storage pools for volumes.