The website "www.emc.com" has been discontinued. Replace the outdated link "https://www.emc.com/collateral/white-papers/h15088-dell-emc-unity-replication-technologies.pdf" with the link "https://dl.dell.com/content/docu69886_dell-emc-unity-replication-technologies-a-detailed-review.pdf". Change-Id: I3ab2cc28bef7524cec4f161c9d5417597df56b89
677 lines
21 KiB
ReStructuredText
677 lines
21 KiB
ReStructuredText
=====================
|
|
Dell Unity driver
|
|
=====================
|
|
|
|
Unity driver has been integrated in the OpenStack Block Storage project since
|
|
the Ocata release. The driver is built on the top of Block Storage framework
|
|
and a Dell distributed Python package
|
|
`storops <https://pypi.org/project/storops>`_.
|
|
|
|
Prerequisites
|
|
~~~~~~~~~~~~~
|
|
|
|
+-------------------+-----------------+
|
|
| Software | Version |
|
|
+===================+=================+
|
|
| Unity OE | 4.1.X or newer |
|
|
+-------------------+-----------------+
|
|
| storops | 1.2.3 or newer |
|
|
+-------------------+-----------------+
|
|
|
|
|
|
Supported operations
|
|
~~~~~~~~~~~~~~~~~~~~
|
|
|
|
- Create, delete, attach, and detach volumes.
|
|
- Create, delete, attach, and detach compressed volumes.
|
|
- Create, list, and delete volume snapshots.
|
|
- Create a volume from a snapshot.
|
|
- Copy an image to a volume.
|
|
- Create an image from a volume.
|
|
- Clone a volume.
|
|
- Extend a volume.
|
|
- Migrate a volume.
|
|
- Get volume statistics.
|
|
- Efficient non-disruptive volume backup.
|
|
- Revert a volume to a snapshot.
|
|
- Create thick volumes.
|
|
- Create volume with tiering policy.
|
|
- Create and delete consistent groups.
|
|
- Add/remove volumes to/from a consistent group.
|
|
- Create and delete consistent group snapshots.
|
|
- Clone a consistent group.
|
|
- Create a consistent group from a snapshot.
|
|
- Attach a volume to multiple servers simultaneously (multiattach).
|
|
- Volume replications.
|
|
- Consistency group replications.
|
|
|
|
Driver configuration
|
|
~~~~~~~~~~~~~~~~~~~~
|
|
|
|
.. note:: The following instructions should all be performed on
|
|
cinder-volume container.
|
|
|
|
#. Install `storops` from pypi:
|
|
|
|
.. code-block:: console
|
|
|
|
# pip install storops
|
|
|
|
|
|
#. Add the following content into ``/etc/cinder/cinder.conf``:
|
|
|
|
.. code-block:: ini
|
|
|
|
[DEFAULT]
|
|
enabled_backends = unity
|
|
|
|
[unity]
|
|
# Storage protocol
|
|
storage_protocol = iSCSI
|
|
# Unisphere IP
|
|
san_ip = <SAN IP>
|
|
# Unisphere username and password
|
|
san_login = <SAN LOGIN>
|
|
san_password = <SAN PASSWORD>
|
|
# Volume driver name
|
|
volume_driver = cinder.volume.drivers.dell_emc.unity.Driver
|
|
# backend's name
|
|
volume_backend_name = Storage_ISCSI_01
|
|
|
|
.. note:: These are minimal options for Unity driver, for more options,
|
|
see `Driver options`_.
|
|
|
|
|
|
.. note:: (**Optional**) If you require multipath based data access, perform
|
|
below steps on both Block Storage and Compute nodes.
|
|
|
|
|
|
#. Install ``sysfsutils``, ``sg3-utils`` and ``multipath-tools``:
|
|
|
|
.. code-block:: console
|
|
|
|
# apt-get install multipath-tools sg3-utils sysfsutils
|
|
|
|
|
|
#. (Required for FC driver in case `Auto-zoning Support`_ is disabled) Zone the
|
|
FC ports of Compute nodes with Unity FC target ports.
|
|
|
|
|
|
#. Enable Unity storage optimized multipath configuration:
|
|
|
|
Add the following content into ``/etc/multipath.conf``
|
|
|
|
.. code-block:: vim
|
|
|
|
blacklist {
|
|
# Skip the files uner /dev that are definitely not FC/iSCSI devices
|
|
# Different system may need different customization
|
|
devnode "^(ram|raw|loop|fd|md|dm-|sr|scd|st)[0-9]*"
|
|
devnode "^hd[a-z][0-9]*"
|
|
devnode "^cciss!c[0-9]d[0-9]*[p[0-9]*]"
|
|
|
|
# Skip LUNZ device from VNX/Unity
|
|
device {
|
|
vendor "DGC"
|
|
product "LUNZ"
|
|
}
|
|
}
|
|
|
|
defaults {
|
|
user_friendly_names no
|
|
flush_on_last_del yes
|
|
}
|
|
|
|
devices {
|
|
# Device attributed for EMC CLARiiON and VNX/Unity series ALUA
|
|
device {
|
|
vendor "DGC"
|
|
product ".*"
|
|
product_blacklist "LUNZ"
|
|
path_grouping_policy group_by_prio
|
|
path_selector "round-robin 0"
|
|
path_checker emc_clariion
|
|
features "0"
|
|
no_path_retry 12
|
|
hardware_handler "1 alua"
|
|
prio alua
|
|
failback immediate
|
|
}
|
|
}
|
|
|
|
|
|
#. Restart the multipath service:
|
|
|
|
.. code-block:: console
|
|
|
|
# service multipath-tools restart
|
|
|
|
|
|
#. Enable multipath for image transfer in ``/etc/cinder/cinder.conf`` for each
|
|
backend or in ``[backend_defaults]`` section as a common configuration
|
|
for all backends.
|
|
|
|
.. code-block:: ini
|
|
|
|
use_multipath_for_image_xfer = True
|
|
|
|
Restart the ``cinder-volume`` service to load the change.
|
|
|
|
#. Enable multipath for volume attache/detach in ``/etc/nova/nova.conf``.
|
|
|
|
.. code-block:: ini
|
|
|
|
[libvirt]
|
|
...
|
|
volume_use_multipath = True
|
|
...
|
|
|
|
#. Restart the ``nova-compute`` service.
|
|
|
|
Driver options
|
|
~~~~~~~~~~~~~~
|
|
|
|
.. config-table::
|
|
:config-target: Unity
|
|
|
|
cinder.volume.drivers.dell_emc.unity.driver
|
|
|
|
FC or iSCSI ports option
|
|
------------------------
|
|
|
|
Specify the list of FC or iSCSI ports to be used to perform the IO. Wild card
|
|
character is supported.
|
|
For iSCSI ports, use the following format:
|
|
|
|
.. code-block:: ini
|
|
|
|
unity_io_ports = spa_eth2, spb_eth2, *_eth3
|
|
|
|
For FC ports, use the following format:
|
|
|
|
.. code-block:: ini
|
|
|
|
unity_io_ports = spa_iom_0_fc0, spb_iom_0_fc0, *_iom_0_fc1
|
|
|
|
List the port ID with the :command:`uemcli` command:
|
|
|
|
.. code-block:: console
|
|
|
|
$ uemcli /net/port/eth show -output csv
|
|
...
|
|
"spa_eth2","SP A Ethernet Port 2","spa","file, net, iscsi", ...
|
|
"spb_eth2","SP B Ethernet Port 2","spb","file, net, iscsi", ...
|
|
...
|
|
|
|
$ uemcli /net/port/fc show -output csv
|
|
...
|
|
"spa_iom_0_fc0","SP A I/O Module 0 FC Port 0","spa", ...
|
|
"spb_iom_0_fc0","SP B I/O Module 0 FC Port 0","spb", ...
|
|
...
|
|
|
|
Live migration integration
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
It is suggested to have multipath configured on Compute nodes for robust data
|
|
access in VM instances live migration scenario. Once ``user_friendly_names no``
|
|
is set in defaults section of ``/etc/multipath.conf``, Compute nodes will use
|
|
the WWID as the alias for the multipath devices.
|
|
|
|
To enable multipath in live migration:
|
|
|
|
.. note:: Make sure `Driver configuration`_ steps are performed before
|
|
following steps.
|
|
|
|
#. Set multipath in ``/etc/nova/nova.conf``:
|
|
|
|
.. code-block:: ini
|
|
|
|
[libvirt]
|
|
...
|
|
volume_use_multipath = True
|
|
...
|
|
|
|
Restart `nova-compute` service.
|
|
|
|
|
|
#. Set ``user_friendly_names no`` in ``/etc/multipath.conf``
|
|
|
|
.. code-block:: text
|
|
|
|
...
|
|
defaults {
|
|
user_friendly_names no
|
|
}
|
|
...
|
|
|
|
#. Restart the ``multipath-tools`` service.
|
|
|
|
|
|
Thin and thick provisioning
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
By default, the volume created by Unity driver is thin provisioned. Run the
|
|
following commands to create a thick volume.
|
|
|
|
.. code-block:: console
|
|
|
|
# openstack volume type create --property provisioning:type=thick \
|
|
--property thick_provisioning_support='<is> True' thick_volume_type
|
|
# openstack volume create --type thick_volume_type thick_volume
|
|
|
|
|
|
Compressed volume support
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
Unity driver supports ``compressed volume`` creation, modification and
|
|
deletion. In order to create a compressed volume, a volume type which
|
|
enables compression support needs to be created first:
|
|
|
|
.. code-block:: console
|
|
|
|
$ openstack volume type create CompressedVolumeType
|
|
$ openstack volume type set --property provisioning:type=compressed --property compression_support='<is> True' CompressedVolumeType
|
|
|
|
Then create volume and specify the new created volume type.
|
|
|
|
.. note:: In Unity, only All-Flash pools support compressed volume, for the
|
|
other type of pools, "'compression_support': False" will be
|
|
returned when getting pool stats.
|
|
|
|
|
|
Storage-assisted volume migration support
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
Unity driver supports storage-assisted volume migration, when the user starts
|
|
migrating with ``cinder migrate --force-host-copy False <volume_id> <host>`` or
|
|
``cinder migrate <volume_id> <host>``, cinder will try to leverage the Unity's
|
|
native volume migration functionality. If Unity fails to migrate the volume,
|
|
host-assisted migration will be triggered.
|
|
|
|
In the following scenarios, Unity storage-assisted volume migration will not be
|
|
triggered. Instead, host-assisted volume migration will be triggered:
|
|
|
|
- Volume is to be migrated across backends.
|
|
- Migration of cloned volume. For example, if vol_2 was cloned from vol_1,
|
|
the storage-assisted volume migration of vol_2 will not be triggered.
|
|
|
|
|
|
Retype volume support
|
|
~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
Unity driver supports to change a volume's type after its creation.
|
|
|
|
.. code-block:: console
|
|
|
|
$ cinder retype [--migration-policy <never|on-demand>] <volume> <volume-type>
|
|
|
|
The --migration-policy is not enabled by default.
|
|
Some retype operations will require migration based on back-end support.
|
|
In these cases, the storage-assisted migration will be triggered regardless
|
|
the --migration-policy. For examples: retype between 'thin' and 'thick', retype
|
|
between 'thick' and 'compressed', retype to type(s) current host doesn't
|
|
support.
|
|
|
|
|
|
QoS support
|
|
~~~~~~~~~~~
|
|
|
|
Unity driver supports ``maxBWS`` and ``maxIOPS`` specs for the back-end
|
|
consumer type. ``maxBWS`` represents the ``Maximum Bandwidth (KBPS)`` absolute
|
|
limit, ``maxIOPS`` represents the ``Maximum IO/S`` absolute limit on the
|
|
Unity respectively.
|
|
|
|
|
|
Storage tiering support
|
|
~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
Unity supports fully automated storage tiering which requires the FAST VP
|
|
license activated on the Unity. The OpenStack administrator can use the extra
|
|
spec key ``storagetype:tiering`` to set the tiering policy of a volume and
|
|
use the key ``fast_support='<is> True'`` to let Block Storage scheduler find
|
|
a volume back end which manages a Unity with FAST VP license activated. There
|
|
are four supported values for the extra spec key ``storagetype:tiering``
|
|
when creating volume.
|
|
|
|
- Key: ``storagetype:tiering``
|
|
- Possible values:
|
|
|
|
- ``StartHighThenAuto``
|
|
- ``Auto``
|
|
- ``HighestAvailable``
|
|
- ``LowestAvailable``
|
|
|
|
- Default: ``StartHighThenAuto``
|
|
|
|
Run the following commands to create a volume type with tiering policy:
|
|
|
|
.. code-block:: console
|
|
|
|
$ openstack volume type create VolumeOnAutoTier
|
|
$ openstack volume type set --property storagetype:tiering=Auto --property fast_support='<is> True' VolumeOnAutoTier
|
|
|
|
|
|
Auto-zoning support
|
|
~~~~~~~~~~~~~~~~~~~
|
|
|
|
Unity volume driver supports auto-zoning, and share the same configuration
|
|
guide for other vendors. Refer to :ref:`fc_zone_manager`
|
|
for detailed configuration steps.
|
|
|
|
Solution for LUNZ device
|
|
~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
The EMC host team also found LUNZ on all of the hosts, EMC best practice is to
|
|
present a LUN with HLU 0 to clear any LUNZ devices as they can cause issues on
|
|
the host. See KB `LUNZ Device <https://support.emc.com/kb/463402>`_.
|
|
|
|
To workaround this issue, Unity driver creates a `Dummy LUN` (if not present),
|
|
and adds it to each host to occupy the `HLU 0` during volume attachment.
|
|
|
|
.. note:: This `Dummy LUN` is shared among all hosts connected to the Unity.
|
|
|
|
Efficient non-disruptive volume backup
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
The default implementation in Block Storage for non-disruptive volume backup is
|
|
not efficient since a cloned volume will be created during backup.
|
|
|
|
An effective approach to backups is to create a snapshot for the volume and
|
|
connect this snapshot to the Block Storage host for volume backup.
|
|
|
|
SSL support
|
|
~~~~~~~~~~~
|
|
|
|
Admin is able to enable the SSL verification for any communication against
|
|
Unity REST API.
|
|
|
|
By default, the SSL verification is disabled, user can enable it by following
|
|
steps:
|
|
|
|
#. Setup the Unity array certificate and import it to the Unity, see section
|
|
`Storage system certificate` of `Security Configuration Guide <https://www.emc.com/collateral/TechnicalDocument/docu69321.pdf>`_.
|
|
|
|
#. Import the CA certificate to the Cinder nodes on which the driver is
|
|
running.
|
|
|
|
#. Enable the changes on cinder nodes and restart the cinder services.
|
|
|
|
.. code-block:: ini
|
|
|
|
[unity]
|
|
...
|
|
driver_ssl_cert_verify = True
|
|
driver_ssl_cert_path = <path to the CA>
|
|
...
|
|
|
|
|
|
If `driver_ssl_cert_path` is omitted, the system default CA will be used for CA
|
|
verification.
|
|
|
|
|
|
IPv6 support
|
|
~~~~~~~~~~~~
|
|
|
|
This driver can support IPv6-based control path and data path.
|
|
|
|
For control path, please follow below steps:
|
|
|
|
- Enable Unity's Unipshere IPv6 address.
|
|
- Configure the IPv6 network to make sure that cinder node can access Unishpere
|
|
via IPv6 address.
|
|
- Change Cinder config file ``/etc/cinder/cinder.conf``. Make the ``san_ip``
|
|
as Unisphere IPv6 address. For example, ``san_ip = [fd99:f17b:37d0::100]``.
|
|
- Restart the Cinder service to make new configuration take effect.
|
|
|
|
**Note**: The IPv6 support on control path depends on the fix of cpython
|
|
`bug 32185 <https://bugs.python.org/issue32185>`__. Please make sure your
|
|
Python's version includes this bug's fix.
|
|
|
|
For data path, please follow below steps:
|
|
|
|
- On Unity, Create iSCSI interface with IPv6 address.
|
|
- Configure the IPv6 network to make sure that you can ``ping``
|
|
the Unity's iSCSI IPv6 address from the Cinder node.
|
|
- If you create a volume using Cinder and attach it to a VM,
|
|
the connection between this VM and volume will be IPv6-based iSCSI.
|
|
|
|
Force detach volume from all hosts
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
The user could use `os-force_detach` action to detach a volume from all its
|
|
attached hosts.
|
|
For more detail, please refer to
|
|
https://docs.openstack.org/api-ref/block-storage/v3/?expanded=force-detach-a-volume-detail#force-detach-a-volume
|
|
|
|
Consistent group support
|
|
~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
For a group to support consistent group snapshot, the group specs in the
|
|
corresponding group type should have the following entry:
|
|
|
|
.. code-block:: ini
|
|
|
|
{'consistent_group_snapshot_enabled': <is> True}
|
|
|
|
Similarly, for a volume to be in a group that supports consistent group
|
|
snapshots, the volume type extra specs would also have the following entry:
|
|
|
|
.. code-block:: ini
|
|
|
|
{'consistent_group_snapshot_enabled': <is> True}
|
|
|
|
Refer to :doc:`/admin/groups`
|
|
for command lines detail.
|
|
|
|
Volume replications
|
|
~~~~~~~~~~~~~~~~~~~
|
|
|
|
To enable volume replications, follow below steps:
|
|
|
|
1. On Unisphere, configure remote system and interfaces for replications.
|
|
|
|
The way could be different depending on the type of replications - sync or async.
|
|
Refer to `Unity Replication White Paper
|
|
<https://dl.dell.com/content/docu69886_dell-emc-unity-replication-technologies-a-detailed-review.pdf>`_
|
|
for more detail.
|
|
|
|
2. Add `replication_device` to storage backend settings in `cinder.conf`, then
|
|
restart Cinder Volume service.
|
|
|
|
Example of `cinder.conf` for volume replications:
|
|
|
|
.. code-block:: ini
|
|
|
|
[unity-primary]
|
|
san_ip = xxx.xxx.xxx.xxx
|
|
...
|
|
replication_device = backend_id:unity-secondary,san_ip:yyy.yyy.yyy.yyy,san_login:username,san_password:****,max_time_out_of_sync:60
|
|
|
|
- Only one `replication_device` can be configured for each primary backend.
|
|
- Keys `backend_id`, `san_ip`, `san_password`, and `max_time_out_of_sync`
|
|
are supported in `replication_device`, while `backend_id` and `san_ip`
|
|
are required.
|
|
- `san_password` uses the same one as primary backend's if it is omitted.
|
|
- `max_time_out_of_sync` is the max time in minutes replications are out of
|
|
sync. It must be equal or greater than `0`. `0` means sync replications
|
|
of volumes will be created. Note that remote systems for sync replications
|
|
need to be created on Unity first. `60` will be used if it is omitted.
|
|
|
|
#. Create a volume type with property `replication_enabled='<is> True'`.
|
|
|
|
.. code-block:: console
|
|
|
|
$ openstack volume type create --property replication_enabled='<is> True' type-replication
|
|
|
|
#. Any volumes with volume type of step #3 will failover to secondary backend
|
|
after `failover_host` is executed.
|
|
|
|
.. code-block:: console
|
|
|
|
$ cinder failover-host --backend_id unity-secondary stein@unity-primary
|
|
|
|
#. Later, they could be failed back.
|
|
|
|
.. code-block:: console
|
|
|
|
$ cinder failover-host --backend_id default stein@unity-primary
|
|
|
|
.. note:: The volume can be deleted even when it is participating in a
|
|
replication. The replication session will be deleted from Unity before the
|
|
LUN is deleted.
|
|
|
|
Consistency group replications
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
To enable consistency group replications, follow below steps:
|
|
|
|
1. On Unisphere, configure remote system and interfaces for replications.
|
|
|
|
The way could be different depending on the type of replications - sync or async.
|
|
Refer to `Unity Replication White Paper
|
|
<https://dl.dell.com/content/docu69886_dell-emc-unity-replication-technologies-a-detailed-review.pdf>`_
|
|
for more detail.
|
|
|
|
2. Add `replication_device` to storage backend settings in `cinder.conf`, then
|
|
restart Cinder Volume service.
|
|
|
|
Example of `cinder.conf` for volume replications:
|
|
|
|
.. code-block:: ini
|
|
|
|
[unity-primary]
|
|
san_ip = xxx.xxx.xxx.xxx
|
|
...
|
|
replication_device = backend_id:unity-secondary,san_ip:yyy.yyy.yyy.yyy,san_login:username,san_password:****,max_time_out_of_sync:60
|
|
|
|
- Only one `replication_device` can be configured for each primary backend.
|
|
- Keys `backend_id`, `san_ip`, `san_password`, and `max_time_out_of_sync`
|
|
are supported in `replication_device`, while `backend_id` and `san_ip`
|
|
are required.
|
|
- `san_password` uses the same one as primary backend's if it is omitted.
|
|
- `max_time_out_of_sync` is the max time in minutes replications are out of
|
|
sync. It must be equal or greater than `0`. `0` means sync replications
|
|
of volumes will be created. Note that remote systems for sync replications
|
|
need to be created on Unity first. `60` will be used if it is omitted.
|
|
|
|
3. Create a volume type with property `replication_enabled='<is> True'`.
|
|
|
|
.. code-block:: console
|
|
|
|
$ openstack volume type create --property replication_enabled='<is> True' type-replication
|
|
|
|
4. Create a consistency group type with properties
|
|
`consistent_group_snapshot_enabled='<is> True'`
|
|
and `consistent_group_replication_enabled='<is> True'`.
|
|
|
|
.. code-block:: console
|
|
|
|
$ cinder --os-volume-api-version 3.38 group-type-create type-cg-replication
|
|
$ cinder --os-volume-api-version 3.38 group-type-key type-cg-replication set
|
|
consistent_group_snapshot_enabled='<is> True' consistent_group_replication_enabled='<is> True'
|
|
|
|
5. Create a group type with volume types support replication.
|
|
|
|
.. code-block:: console
|
|
|
|
$ cinder --os-volume-api-version 3.38 group-create --name test-cg {type-cg-replication-id} type-replication
|
|
|
|
6. Create volume in the consistency group.
|
|
|
|
.. code-block:: console
|
|
|
|
$ cinder --os-volume-api-version 3.38 create --volume-type type-replication --group-id {test-cg-id}
|
|
--name {volume-name} {size}
|
|
|
|
7. Enable consistency group replication.
|
|
|
|
.. code-block:: console
|
|
|
|
$ cinder --os-volume-api-version 3.38 group-enable-replication test-cg
|
|
|
|
8. Disable consistency group replication.
|
|
|
|
.. code-block:: console
|
|
|
|
$ cinder --os-volume-api-version 3.38 group-disable-replication test-cg
|
|
|
|
9. Failover consistency group replication.
|
|
|
|
.. code-block:: console
|
|
|
|
$ cinder --os-volume-api-version 3.38 group-failover-replication test-cg
|
|
|
|
10. Failback consistency group replication.
|
|
|
|
.. code-block:: console
|
|
|
|
$ cinder --os-volume-api-version 3.38 group-failover-replication test-cg --secondary-backend-id default
|
|
|
|
.. note:: Only support group replication of consistency group,
|
|
see step 4 and 5 to create consistency group support replication.
|
|
|
|
|
|
Troubleshooting
|
|
~~~~~~~~~~~~~~~
|
|
|
|
To troubleshoot a failure in OpenStack deployment, the best way is to
|
|
enable verbose and debug log, at the same time, leverage the build-in
|
|
`Return request ID to caller
|
|
<https://specs.openstack.org/openstack/openstack-specs/specs/return-request-id.html>`_
|
|
to track specific Block Storage command logs.
|
|
|
|
|
|
#. Enable verbose log, set following in ``/etc/cinder/cinder.conf`` and restart
|
|
all Block Storage services:
|
|
|
|
.. code-block:: ini
|
|
|
|
[DEFAULT]
|
|
|
|
...
|
|
|
|
debug = True
|
|
verbose = True
|
|
|
|
...
|
|
|
|
|
|
If other projects (usually Compute) are also involved, set `debug`
|
|
and ``verbose`` to ``True``.
|
|
|
|
#. use ``--debug`` to trigger any problematic Block Storage operation:
|
|
|
|
.. code-block:: console
|
|
|
|
# cinder --debug create --name unity_vol1 100
|
|
|
|
|
|
You will see the request ID from the console, for example:
|
|
|
|
.. code-block:: console
|
|
|
|
DEBUG:keystoneauth:REQ: curl -g -i -X POST
|
|
http://192.168.1.9:8776/v2/e50d22bdb5a34078a8bfe7be89324078/volumes -H
|
|
"User-Agent: python-cinderclient" -H "Content-Type: application/json" -H
|
|
"Accept: application/json" -H "X-Auth-Token:
|
|
{SHA1}bf4a85ad64302b67a39ad7c6f695a9630f39ab0e" -d '{"volume": {"status":
|
|
"creating", "user_id": null, "name": "unity_vol1", "imageRef": null,
|
|
"availability_zone": null, "description": null, "multiattach": false,
|
|
"attach_status": "detached", "volume_type": null, "metadata": {},
|
|
"consistencygroup_id": null, "source_volid": null, "snapshot_id": null,
|
|
"project_id": null, "source_replica": null, "size": 10}}'
|
|
DEBUG:keystoneauth:RESP: [202] X-Compute-Request-Id:
|
|
req-3a459e0e-871a-49f9-9796-b63cc48b5015 Content-Type: application/json
|
|
Content-Length: 804 X-Openstack-Request-Id:
|
|
req-3a459e0e-871a-49f9-9796-b63cc48b5015 Date: Mon, 12 Dec 2016 09:31:44 GMT
|
|
Connection: keep-alive
|
|
|
|
#. Use commands like ``grep``, ``awk`` to find the error related to the Block
|
|
Storage operations.
|
|
|
|
.. code-block:: console
|
|
|
|
# grep "req-3a459e0e-871a-49f9-9796-b63cc48b5015" cinder-volume.log
|
|
|
|
|