It was discovered today that the 'config-reference' directory was supposed to have been renamed to 'configuration'. The doc team was expecting it to be at that location so that they could automatically link to it from contributor/index.html . This patch just moves the directory. I am going to be submitting a subsequent patch that properly sets out the framework for the additional directories so that we don't have addition problems in the future. Change-Id: I6729aaf4593a0b089277f6d7d0aa50fee3ca340f
243 lines
6.8 KiB
ReStructuredText
243 lines
6.8 KiB
ReStructuredText
=============================
|
|
IBM FlashSystem volume driver
|
|
=============================
|
|
|
|
The volume driver for FlashSystem provides OpenStack Block Storage hosts
|
|
with access to IBM FlashSystems.
|
|
|
|
Configure FlashSystem
|
|
~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
Configure storage array
|
|
-----------------------
|
|
|
|
The volume driver requires a pre-defined array. You must create an
|
|
array on the FlashSystem before using the volume driver. An existing array
|
|
can also be used and existing data will not be deleted.
|
|
|
|
.. note::
|
|
|
|
FlashSystem can only create one array, so no configuration option is
|
|
needed for the IBM FlashSystem driver to assign it.
|
|
|
|
Configure user authentication for the driver
|
|
--------------------------------------------
|
|
|
|
The driver requires access to the FlashSystem management interface using
|
|
SSH. It should be provided with the FlashSystem management IP using the
|
|
``san_ip`` flag, and the management port should be provided by the
|
|
``san_ssh_port`` flag. By default, the port value is configured to be
|
|
port 22 (SSH).
|
|
|
|
.. note::
|
|
|
|
Make sure the compute node running the ``cinder-volume`` driver has SSH
|
|
network access to the storage system.
|
|
|
|
Using password authentication, assign a password to the user on the
|
|
FlashSystem. For more detail, see the driver configuration flags
|
|
for the user and password here: :ref:`config_fc_flags`
|
|
or :ref:`config_iscsi_flags`.
|
|
|
|
IBM FlashSystem FC driver
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
Data Path configuration
|
|
-----------------------
|
|
|
|
Using Fiber Channel (FC), each FlashSystem node should have at least one
|
|
WWPN port configured. If the ``flashsystem_multipath_enabled`` flag is
|
|
set to ``True`` in the Block Storage service configuration file, the driver
|
|
uses all available WWPNs to attach the volume to the instance. If the flag is
|
|
not set, the driver uses the WWPN associated with the volume's preferred node
|
|
(if available). Otherwise, it uses the first available WWPN of the system. The
|
|
driver obtains the WWPNs directly from the storage system. You do not need to
|
|
provide these WWPNs to the driver.
|
|
|
|
.. note::
|
|
|
|
Using FC, ensure that the block storage hosts have FC connectivity
|
|
to the FlashSystem.
|
|
|
|
.. _config_fc_flags:
|
|
|
|
Enable IBM FlashSystem FC driver
|
|
--------------------------------
|
|
|
|
Set the volume driver to the FlashSystem driver by setting the
|
|
``volume_driver`` option in the ``cinder.conf`` configuration file,
|
|
as follows:
|
|
|
|
.. code-block:: ini
|
|
|
|
volume_driver = cinder.volume.drivers.ibm.flashsystem_fc.FlashSystemFCDriver
|
|
|
|
To enable the IBM FlashSystem FC driver, configure the following options in the
|
|
``cinder.conf`` configuration file:
|
|
|
|
.. list-table:: List of configuration flags for IBM FlashSystem FC driver
|
|
:header-rows: 1
|
|
|
|
* - Flag name
|
|
- Type
|
|
- Default
|
|
- Description
|
|
* - ``san_ip``
|
|
- Required
|
|
-
|
|
- Management IP or host name
|
|
* - ``san_ssh_port``
|
|
- Optional
|
|
- 22
|
|
- Management port
|
|
* - ``san_login``
|
|
- Required
|
|
-
|
|
- Management login user name
|
|
* - ``san_password``
|
|
- Required
|
|
-
|
|
- Management login password
|
|
* - ``flashsystem_connection_protocol``
|
|
- Required
|
|
-
|
|
- Connection protocol should be set to ``FC``
|
|
* - ``flashsystem_multipath_enabled``
|
|
- Required
|
|
-
|
|
- Enable multipath for FC connections
|
|
* - ``flashsystem_multihost_enabled``
|
|
- Optional
|
|
- ``True``
|
|
- Enable mapping vdisks to multiple hosts [1]_
|
|
|
|
.. [1]
|
|
This option allows the driver to map a vdisk to more than one host at
|
|
a time. This scenario occurs during migration of a virtual machine
|
|
with an attached volume; the volume is simultaneously mapped to both
|
|
the source and destination compute hosts. If your deployment does not
|
|
require attaching vdisks to multiple hosts, setting this flag to
|
|
``False`` will provide added safety.
|
|
|
|
IBM FlashSystem iSCSI driver
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
Network configuration
|
|
---------------------
|
|
|
|
Using iSCSI, each FlashSystem node should have at least one iSCSI port
|
|
configured. iSCSI IP addresses of IBM FlashSystem can be obtained by
|
|
FlashSystem GUI or CLI. For more information, see the
|
|
appropriate IBM Redbook for the FlashSystem.
|
|
|
|
.. note::
|
|
|
|
Using iSCSI, ensure that the compute nodes have iSCSI network access
|
|
to the IBM FlashSystem.
|
|
|
|
.. _config_iscsi_flags:
|
|
|
|
Enable IBM FlashSystem iSCSI driver
|
|
-----------------------------------
|
|
|
|
Set the volume driver to the FlashSystem driver by setting the
|
|
``volume_driver`` option in the ``cinder.conf`` configuration file, as
|
|
follows:
|
|
|
|
.. code-block:: ini
|
|
|
|
volume_driver = cinder.volume.drivers.ibm.flashsystem_iscsi.FlashSystemISCSIDriver
|
|
|
|
To enable IBM FlashSystem iSCSI driver, configure the following options
|
|
in the ``cinder.conf`` configuration file:
|
|
|
|
|
|
.. list-table:: List of configuration flags for IBM FlashSystem iSCSI driver
|
|
:header-rows: 1
|
|
|
|
* - Flag name
|
|
- Type
|
|
- Default
|
|
- Description
|
|
* - ``san_ip``
|
|
- Required
|
|
-
|
|
- Management IP or host name
|
|
* - ``san_ssh_port``
|
|
- Optional
|
|
- 22
|
|
- Management port
|
|
* - ``san_login``
|
|
- Required
|
|
-
|
|
- Management login user name
|
|
* - ``san_password``
|
|
- Required
|
|
-
|
|
- Management login password
|
|
* - ``flashsystem_connection_protocol``
|
|
- Required
|
|
-
|
|
- Connection protocol should be set to ``iSCSI``
|
|
* - ``flashsystem_multihost_enabled``
|
|
- Optional
|
|
- ``True``
|
|
- Enable mapping vdisks to multiple hosts [2]_
|
|
* - ``iscsi_ip_address``
|
|
- Required
|
|
-
|
|
- Set to one of the iSCSI IP addresses obtained by FlashSystem GUI or CLI [3]_
|
|
* - ``flashsystem_iscsi_portid``
|
|
- Required
|
|
-
|
|
- Set to the id of the ``iscsi_ip_address`` obtained by FlashSystem GUI or CLI [4]_
|
|
|
|
.. [2]
|
|
This option allows the driver to map a vdisk to more than one host at
|
|
a time. This scenario occurs during migration of a virtual machine
|
|
with an attached volume; the volume is simultaneously mapped to both
|
|
the source and destination compute hosts. If your deployment does not
|
|
require attaching vdisks to multiple hosts, setting this flag to
|
|
``False`` will provide added safety.
|
|
|
|
.. [3]
|
|
On the cluster of the FlashSystem, the ``iscsi_ip_address`` column is the
|
|
seventh column ``IP_address`` of the output of ``lsportip``.
|
|
|
|
.. [4]
|
|
On the cluster of the FlashSystem, port ID column is the first
|
|
column ``id`` of the output of ``lsportip``,
|
|
not the sixth column ``port_id``.
|
|
|
|
Limitations and known issues
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
IBM FlashSystem only works when:
|
|
|
|
.. code-block:: ini
|
|
|
|
open_access_enabled=off
|
|
|
|
Supported operations
|
|
~~~~~~~~~~~~~~~~~~~~
|
|
|
|
These operations are supported:
|
|
|
|
- Create, delete, attach, and detach volumes.
|
|
|
|
- Create, list, and delete volume snapshots.
|
|
|
|
- Create a volume from a snapshot.
|
|
|
|
- Copy an image to a volume.
|
|
|
|
- Copy a volume to an image.
|
|
|
|
- Clone a volume.
|
|
|
|
- Extend a volume.
|
|
|
|
- Get volume statistics.
|
|
|
|
- Manage and unmanage a volume.
|