It was discovered today that the 'config-reference' directory was supposed to have been renamed to 'configuration'. The doc team was expecting it to be at that location so that they could automatically link to it from contributor/index.html . This patch just moves the directory. I am going to be submitting a subsequent patch that properly sets out the framework for the additional directories so that we don't have addition problems in the future. Change-Id: I6729aaf4593a0b089277f6d7d0aa50fee3ca340f
593 lines
23 KiB
ReStructuredText
593 lines
23 KiB
ReStructuredText
=====================
|
||
NetApp unified driver
|
||
=====================
|
||
|
||
The NetApp unified driver is a Block Storage driver that supports
|
||
multiple storage families and protocols. A storage family corresponds to
|
||
storage systems built on different NetApp technologies such as clustered
|
||
Data ONTAP, Data ONTAP operating in 7-Mode, and E-Series. The storage
|
||
protocol refers to the protocol used to initiate data storage and access
|
||
operations on those storage systems like iSCSI and NFS. The NetApp
|
||
unified driver can be configured to provision and manage OpenStack
|
||
volumes on a given storage family using a specified storage protocol.
|
||
Also, the NetApp unified driver supports over subscription or over
|
||
provisioning when thin provisioned Block Storage volumes are in use
|
||
on an E-Series backend. The OpenStack volumes can then be used for
|
||
accessing and storing data using the storage protocol on the storage
|
||
family system. The NetApp unified driver is an extensible interface
|
||
that can support new storage families and protocols.
|
||
|
||
.. important::
|
||
|
||
The NetApp unified driver in cinder currently provides integration for
|
||
two major generations of the ONTAP operating system: the current
|
||
clustered ONTAP and the legacy 7-mode. NetApp’s full support for
|
||
7-mode ended in August of 2015 and the current limited support period
|
||
will end in February of 2017.
|
||
|
||
The 7-mode components of the cinder NetApp unified driver have now been
|
||
marked deprecated and will be removed in the Queens release. This will
|
||
apply to all three protocols currently supported in this driver: iSCSI,
|
||
FC and NFS.
|
||
|
||
.. note::
|
||
|
||
With the Juno release of OpenStack, Block Storage has
|
||
introduced the concept of storage pools, in which a single
|
||
Block Storage back end may present one or more logical
|
||
storage resource pools from which Block Storage will
|
||
select a storage location when provisioning volumes.
|
||
|
||
In releases prior to Juno, the NetApp unified driver contained some
|
||
scheduling logic that determined which NetApp storage container
|
||
(namely, a FlexVol volume for Data ONTAP, or a dynamic disk pool for
|
||
E-Series) that a new Block Storage volume would be placed into.
|
||
|
||
With the introduction of pools, all scheduling logic is performed
|
||
completely within the Block Storage scheduler, as each
|
||
NetApp storage container is directly exposed to the Block
|
||
Storage scheduler as a storage pool. Previously, the NetApp
|
||
unified driver presented an aggregated view to the scheduler and
|
||
made a final placement decision as to which NetApp storage container
|
||
the Block Storage volume would be provisioned into.
|
||
|
||
NetApp clustered Data ONTAP storage family
|
||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||
|
||
The NetApp clustered Data ONTAP storage family represents a
|
||
configuration group which provides Compute instances access to
|
||
clustered Data ONTAP storage systems. At present it can be configured in
|
||
Block Storage to work with iSCSI and NFS storage protocols.
|
||
|
||
NetApp iSCSI configuration for clustered Data ONTAP
|
||
---------------------------------------------------
|
||
|
||
The NetApp iSCSI configuration for clustered Data ONTAP is an interface
|
||
from OpenStack to clustered Data ONTAP storage systems. It provisions
|
||
and manages the SAN block storage entity, which is a NetApp LUN that
|
||
can be accessed using the iSCSI protocol.
|
||
|
||
The iSCSI configuration for clustered Data ONTAP is a direct interface
|
||
from Block Storage to the clustered Data ONTAP instance and as
|
||
such does not require additional management software to achieve the
|
||
desired functionality. It uses NetApp APIs to interact with the
|
||
clustered Data ONTAP instance.
|
||
|
||
**Configuration options**
|
||
|
||
Configure the volume driver, storage family, and storage protocol to the
|
||
NetApp unified driver, clustered Data ONTAP, and iSCSI respectively by
|
||
setting the ``volume_driver``, ``netapp_storage_family`` and
|
||
``netapp_storage_protocol`` options in the ``cinder.conf`` file as follows:
|
||
|
||
.. code-block:: ini
|
||
|
||
volume_driver = cinder.volume.drivers.netapp.common.NetAppDriver
|
||
netapp_storage_family = ontap_cluster
|
||
netapp_storage_protocol = iscsi
|
||
netapp_vserver = openstack-vserver
|
||
netapp_server_hostname = myhostname
|
||
netapp_server_port = port
|
||
netapp_login = username
|
||
netapp_password = password
|
||
|
||
.. note::
|
||
|
||
To use the iSCSI protocol, you must override the default value of
|
||
``netapp_storage_protocol`` with ``iscsi``.
|
||
|
||
.. include:: ../../tables/cinder-netapp_cdot_iscsi.rst
|
||
|
||
.. note::
|
||
|
||
If you specify an account in the ``netapp_login`` that only has
|
||
virtual storage server (Vserver) administration privileges (rather
|
||
than cluster-wide administration privileges), some advanced features
|
||
of the NetApp unified driver will not work and you may see warnings
|
||
in the Block Storage logs.
|
||
|
||
.. note::
|
||
|
||
The driver supports iSCSI CHAP uni-directional authentication.
|
||
To enable it, set the ``use_chap_auth`` option to ``True``.
|
||
|
||
.. tip::
|
||
|
||
For more information on these options and other deployment and
|
||
operational scenarios, visit the `NetApp OpenStack Deployment and
|
||
Operations
|
||
Guide <http://netapp.github.io/openstack-deploy-ops-guide/>`__.
|
||
|
||
NetApp NFS configuration for clustered Data ONTAP
|
||
-------------------------------------------------
|
||
|
||
The NetApp NFS configuration for clustered Data ONTAP is an interface from
|
||
OpenStack to a clustered Data ONTAP system for provisioning and managing
|
||
OpenStack volumes on NFS exports provided by the clustered Data ONTAP system
|
||
that are accessed using the NFS protocol.
|
||
|
||
The NFS configuration for clustered Data ONTAP is a direct interface from
|
||
Block Storage to the clustered Data ONTAP instance and as such does
|
||
not require any additional management software to achieve the desired
|
||
functionality. It uses NetApp APIs to interact with the clustered Data ONTAP
|
||
instance.
|
||
|
||
**Configuration options**
|
||
|
||
Configure the volume driver, storage family, and storage protocol to NetApp
|
||
unified driver, clustered Data ONTAP, and NFS respectively by setting the
|
||
``volume_driver``, ``netapp_storage_family``, and ``netapp_storage_protocol``
|
||
options in the ``cinder.conf`` file as follows:
|
||
|
||
.. code-block:: ini
|
||
|
||
volume_driver = cinder.volume.drivers.netapp.common.NetAppDriver
|
||
netapp_storage_family = ontap_cluster
|
||
netapp_storage_protocol = nfs
|
||
netapp_vserver = openstack-vserver
|
||
netapp_server_hostname = myhostname
|
||
netapp_server_port = port
|
||
netapp_login = username
|
||
netapp_password = password
|
||
nfs_shares_config = /etc/cinder/nfs_shares
|
||
|
||
.. include:: ../../tables/cinder-netapp_cdot_nfs.rst
|
||
|
||
.. note::
|
||
|
||
Additional NetApp NFS configuration options are shared with the
|
||
generic NFS driver. These options can be found here:
|
||
:ref:`cinder-storage_nfs`.
|
||
|
||
.. note::
|
||
|
||
If you specify an account in the ``netapp_login`` that only has
|
||
virtual storage server (Vserver) administration privileges (rather
|
||
than cluster-wide administration privileges), some advanced features
|
||
of the NetApp unified driver will not work and you may see warnings
|
||
in the Block Storage logs.
|
||
|
||
NetApp NFS Copy Offload client
|
||
------------------------------
|
||
|
||
A feature was added in the Icehouse release of the NetApp unified driver that
|
||
enables Image service images to be efficiently copied to a destination Block
|
||
Storage volume. When the Block Storage and Image service are configured to use
|
||
the NetApp NFS Copy Offload client, a controller-side copy will be attempted
|
||
before reverting to downloading the image from the Image service. This improves
|
||
image provisioning times while reducing the consumption of bandwidth and CPU
|
||
cycles on the host(s) running the Image and Block Storage services. This is due
|
||
to the copy operation being performed completely within the storage cluster.
|
||
|
||
The NetApp NFS Copy Offload client can be used in either of the following
|
||
scenarios:
|
||
|
||
- The Image service is configured to store images in an NFS share that is
|
||
exported from a NetApp FlexVol volume *and* the destination for the new Block
|
||
Storage volume will be on an NFS share exported from a different FlexVol
|
||
volume than the one used by the Image service. Both FlexVols must be located
|
||
within the same cluster.
|
||
|
||
- The source image from the Image service has already been cached in an NFS
|
||
image cache within a Block Storage back end. The cached image resides on a
|
||
different FlexVol volume than the destination for the new Block Storage
|
||
volume. Both FlexVols must be located within the same cluster.
|
||
|
||
To use this feature, you must configure the Image service, as follows:
|
||
|
||
- Set the ``default_store`` configuration option to ``file``.
|
||
|
||
- Set the ``filesystem_store_datadir`` configuration option to the path
|
||
to the Image service NFS export.
|
||
|
||
- Set the ``show_image_direct_url`` configuration option to ``True``.
|
||
|
||
- Set the ``show_multiple_locations`` configuration option to ``True``.
|
||
|
||
- Set the ``filesystem_store_metadata_file`` configuration option to a metadata
|
||
file. The metadata file should contain a JSON object that contains the
|
||
correct information about the NFS export used by the Image service.
|
||
|
||
To use this feature, you must configure the Block Storage service, as follows:
|
||
|
||
- Set the ``netapp_copyoffload_tool_path`` configuration option to the path to
|
||
the NetApp Copy Offload binary.
|
||
|
||
- Set the ``glance_api_version`` configuration option to ``2``.
|
||
|
||
.. important::
|
||
|
||
This feature requires that:
|
||
|
||
- The storage system must have Data ONTAP v8.2 or greater installed.
|
||
|
||
- The vStorage feature must be enabled on each storage virtual machine
|
||
(SVM, also known as a Vserver) that is permitted to interact with the
|
||
copy offload client.
|
||
|
||
- To configure the copy offload workflow, enable NFS v4.0 or greater and
|
||
export it from the SVM.
|
||
|
||
.. tip::
|
||
|
||
To download the NetApp copy offload binary to be utilized in conjunction
|
||
with the ``netapp_copyoffload_tool_path`` configuration option, please visit
|
||
the Utility Toolchest page at the `NetApp Support portal
|
||
<http://mysupport.netapp.com/NOW/download/tools/ntap_openstack_nfs/>`__
|
||
(login is required).
|
||
|
||
.. tip::
|
||
|
||
For more information on these options and other deployment and operational
|
||
scenarios, visit the `NetApp OpenStack Deployment and Operations Guide
|
||
<http://netapp.github.io/openstack-deploy-ops-guide/>`__.
|
||
|
||
NetApp-supported extra specs for clustered Data ONTAP
|
||
-----------------------------------------------------
|
||
|
||
Extra specs enable vendors to specify extra filter criteria.
|
||
The Block Storage scheduler uses the specs when the scheduler determines
|
||
which volume node should fulfill a volume provisioning request.
|
||
When you use the NetApp unified driver with a clustered Data ONTAP
|
||
storage system, you can leverage extra specs with Block Storage
|
||
volume types to ensure that Block Storage volumes are created
|
||
on storage back ends that have certain properties.
|
||
An example of this is when you configure QoS, mirroring,
|
||
or compression for a storage back end.
|
||
|
||
Extra specs are associated with Block Storage volume types.
|
||
When users request volumes of a particular volume type, the volumes
|
||
are created on storage back ends that meet the list of requirements.
|
||
An example of this is the back ends that have the available space or
|
||
extra specs. Use the specs in the following table to configure volumes.
|
||
Define Block Storage volume types by using the :command:`openstack volume
|
||
type set` command.
|
||
|
||
.. include:: ../../tables/manual/cinder-netapp_cdot_extraspecs.rst
|
||
|
||
|
||
NetApp Data ONTAP operating in 7-Mode storage family
|
||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||
|
||
The NetApp Data ONTAP operating in 7-Mode storage family represents a
|
||
configuration group which provides Compute instances access to 7-Mode
|
||
storage systems. At present it can be configured in Block Storage to
|
||
work with iSCSI and NFS storage protocols.
|
||
|
||
NetApp iSCSI configuration for Data ONTAP operating in 7-Mode
|
||
-------------------------------------------------------------
|
||
|
||
The NetApp iSCSI configuration for Data ONTAP operating in 7-Mode is an
|
||
interface from OpenStack to Data ONTAP operating in 7-Mode storage systems for
|
||
provisioning and managing the SAN block storage entity, that is, a LUN which
|
||
can be accessed using iSCSI protocol.
|
||
|
||
The iSCSI configuration for Data ONTAP operating in 7-Mode is a direct
|
||
interface from OpenStack to Data ONTAP operating in 7-Mode storage system and
|
||
it does not require additional management software to achieve the desired
|
||
functionality. It uses NetApp ONTAPI to interact with the Data ONTAP operating
|
||
in 7-Mode storage system.
|
||
|
||
**Configuration options**
|
||
|
||
Configure the volume driver, storage family and storage protocol to the NetApp
|
||
unified driver, Data ONTAP operating in 7-Mode, and iSCSI respectively by
|
||
setting the ``volume_driver``, ``netapp_storage_family`` and
|
||
``netapp_storage_protocol`` options in the ``cinder.conf`` file as follows:
|
||
|
||
.. code-block:: ini
|
||
|
||
volume_driver = cinder.volume.drivers.netapp.common.NetAppDriver
|
||
netapp_storage_family = ontap_7mode
|
||
netapp_storage_protocol = iscsi
|
||
netapp_server_hostname = myhostname
|
||
netapp_server_port = 80
|
||
netapp_login = username
|
||
netapp_password = password
|
||
|
||
.. note::
|
||
|
||
To use the iSCSI protocol, you must override the default value of
|
||
``netapp_storage_protocol`` with ``iscsi``.
|
||
|
||
.. include:: ../../tables/cinder-netapp_7mode_iscsi.rst
|
||
|
||
.. note::
|
||
|
||
The driver supports iSCSI CHAP uni-directional authentication.
|
||
To enable it, set the ``use_chap_auth`` option to ``True``.
|
||
|
||
.. tip::
|
||
|
||
For more information on these options and other deployment and
|
||
operational scenarios, visit the `NetApp OpenStack Deployment and
|
||
Operations
|
||
Guide <http://netapp.github.io/openstack-deploy-ops-guide/>`__.
|
||
|
||
NetApp NFS configuration for Data ONTAP operating in 7-Mode
|
||
-----------------------------------------------------------
|
||
|
||
The NetApp NFS configuration for Data ONTAP operating in 7-Mode is an interface
|
||
from OpenStack to Data ONTAP operating in 7-Mode storage system for
|
||
provisioning and managing OpenStack volumes on NFS exports provided by the Data
|
||
ONTAP operating in 7-Mode storage system which can then be accessed using NFS
|
||
protocol.
|
||
|
||
The NFS configuration for Data ONTAP operating in 7-Mode is a direct interface
|
||
from Block Storage to the Data ONTAP operating in 7-Mode instance and
|
||
as such does not require any additional management software to achieve the
|
||
desired functionality. It uses NetApp ONTAPI to interact with the Data ONTAP
|
||
operating in 7-Mode storage system.
|
||
|
||
|
||
.. important::
|
||
Support for 7-mode configuration has been deprecated in the Ocata release
|
||
and will be removed in the Queens release of OpenStack.
|
||
|
||
**Configuration options**
|
||
|
||
Configure the volume driver, storage family, and storage protocol to the NetApp
|
||
unified driver, Data ONTAP operating in 7-Mode, and NFS respectively by setting
|
||
the ``volume_driver``, ``netapp_storage_family`` and
|
||
``netapp_storage_protocol`` options in the ``cinder.conf`` file as follows:
|
||
|
||
.. code-block:: ini
|
||
|
||
volume_driver = cinder.volume.drivers.netapp.common.NetAppDriver
|
||
netapp_storage_family = ontap_7mode
|
||
netapp_storage_protocol = nfs
|
||
netapp_server_hostname = myhostname
|
||
netapp_server_port = 80
|
||
netapp_login = username
|
||
netapp_password = password
|
||
nfs_shares_config = /etc/cinder/nfs_shares
|
||
|
||
.. include:: ../../tables/cinder-netapp_7mode_nfs.rst
|
||
|
||
.. note::
|
||
|
||
Additional NetApp NFS configuration options are shared with the
|
||
generic NFS driver. For a description of these, see
|
||
:ref:`cinder-storage_nfs`.
|
||
|
||
.. tip::
|
||
|
||
For more information on these options and other deployment and
|
||
operational scenarios, visit the `NetApp OpenStack Deployment and
|
||
Operations
|
||
Guide <http://netapp.github.io/openstack-deploy-ops-guide/>`__.
|
||
|
||
NetApp E-Series storage family
|
||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||
|
||
The NetApp E-Series storage family represents a configuration group which
|
||
provides OpenStack compute instances access to E-Series storage systems. At
|
||
present it can be configured in Block Storage to work with the iSCSI
|
||
storage protocol.
|
||
|
||
NetApp iSCSI configuration for E-Series
|
||
---------------------------------------
|
||
|
||
The NetApp iSCSI configuration for E-Series is an interface from OpenStack to
|
||
E-Series storage systems. It provisions and manages the SAN block storage
|
||
entity, which is a NetApp LUN which can be accessed using the iSCSI protocol.
|
||
|
||
The iSCSI configuration for E-Series is an interface from Block
|
||
Storage to the E-Series proxy instance and as such requires the deployment of
|
||
the proxy instance in order to achieve the desired functionality. The driver
|
||
uses REST APIs to interact with the E-Series proxy instance, which in turn
|
||
interacts directly with the E-Series controllers.
|
||
|
||
The use of multipath and DM-MP are required when using the Block
|
||
Storage driver for E-Series. In order for Block Storage and OpenStack
|
||
Compute to take advantage of multiple paths, the following configuration
|
||
options must be correctly configured:
|
||
|
||
- The ``use_multipath_for_image_xfer`` option should be set to ``True`` in the
|
||
``cinder.conf`` file within the driver-specific stanza (for example,
|
||
``[myDriver]``).
|
||
|
||
- The ``iscsi_use_multipath`` option should be set to ``True`` in the
|
||
``nova.conf`` file within the ``[libvirt]`` stanza.
|
||
|
||
**Configuration options**
|
||
|
||
Configure the volume driver, storage family, and storage protocol to the
|
||
NetApp unified driver, E-Series, and iSCSI respectively by setting the
|
||
``volume_driver``, ``netapp_storage_family`` and
|
||
``netapp_storage_protocol`` options in the ``cinder.conf`` file as follows:
|
||
|
||
.. code-block:: ini
|
||
|
||
volume_driver = cinder.volume.drivers.netapp.common.NetAppDriver
|
||
netapp_storage_family = eseries
|
||
netapp_storage_protocol = iscsi
|
||
netapp_server_hostname = myhostname
|
||
netapp_server_port = 80
|
||
netapp_login = username
|
||
netapp_password = password
|
||
netapp_controller_ips = 1.2.3.4,5.6.7.8
|
||
netapp_sa_password = arrayPassword
|
||
netapp_storage_pools = pool1,pool2
|
||
use_multipath_for_image_xfer = True
|
||
|
||
.. note::
|
||
|
||
To use the E-Series driver, you must override the default value of
|
||
``netapp_storage_family`` with ``eseries``.
|
||
|
||
To use the iSCSI protocol, you must override the default value of
|
||
``netapp_storage_protocol`` with ``iscsi``.
|
||
|
||
.. include:: ../../tables/cinder-netapp_eseries_iscsi.rst
|
||
|
||
.. tip::
|
||
|
||
For more information on these options and other deployment and
|
||
operational scenarios, visit the `NetApp OpenStack Deployment and
|
||
Operations
|
||
Guide <http://netapp.github.io/openstack-deploy-ops-guide/>`__.
|
||
|
||
NetApp-supported extra specs for E-Series
|
||
-----------------------------------------
|
||
|
||
Extra specs enable vendors to specify extra filter criteria.
|
||
The Block Storage scheduler uses the specs when the scheduler determines
|
||
which volume node should fulfill a volume provisioning request.
|
||
When you use the NetApp unified driver with an E-Series storage system,
|
||
you can leverage extra specs with Block Storage volume types to ensure
|
||
that Block Storage volumes are created on storage back ends that have
|
||
certain properties. An example of this is when you configure thin
|
||
provisioning for a storage back end.
|
||
|
||
Extra specs are associated with Block Storage volume types.
|
||
When users request volumes of a particular volume type, the volumes are
|
||
created on storage back ends that meet the list of requirements.
|
||
An example of this is the back ends that have the available space or
|
||
extra specs. Use the specs in the following table to configure volumes.
|
||
Define Block Storage volume types by using the :command:`openstack volume
|
||
type set` command.
|
||
|
||
.. list-table:: Description of extra specs options for NetApp Unified Driver with E-Series
|
||
:header-rows: 1
|
||
|
||
* - Extra spec
|
||
- Type
|
||
- Description
|
||
* - ``netapp_thin_provisioned``
|
||
- Boolean
|
||
- Limit the candidate volume list to only the ones that support thin
|
||
provisioning on the storage controller.
|
||
|
||
Upgrading prior NetApp drivers to the NetApp unified driver
|
||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||
|
||
NetApp introduced a new unified block storage driver in Havana for configuring
|
||
different storage families and storage protocols. This requires defining an
|
||
upgrade path for NetApp drivers which existed in releases prior to Havana. This
|
||
section covers the upgrade configuration for NetApp drivers to the new unified
|
||
configuration and a list of deprecated NetApp drivers.
|
||
|
||
Upgraded NetApp drivers
|
||
-----------------------
|
||
|
||
This section describes how to update Block Storage configuration from
|
||
a pre-Havana release to the unified driver format.
|
||
|
||
- NetApp iSCSI direct driver for Clustered Data ONTAP in Grizzly (or earlier):
|
||
|
||
.. code-block:: ini
|
||
|
||
volume_driver = cinder.volume.drivers.netapp.iscsi.NetAppDirectCmodeISCSIDriver
|
||
|
||
NetApp unified driver configuration:
|
||
|
||
.. code-block:: ini
|
||
|
||
volume_driver = cinder.volume.drivers.netapp.common.NetAppDriver
|
||
netapp_storage_family = ontap_cluster
|
||
netapp_storage_protocol = iscsi
|
||
|
||
- NetApp NFS direct driver for Clustered Data ONTAP in Grizzly (or
|
||
earlier):
|
||
|
||
.. code-block:: ini
|
||
|
||
volume_driver = cinder.volume.drivers.netapp.nfs.NetAppDirectCmodeNfsDriver
|
||
|
||
NetApp unified driver configuration:
|
||
|
||
.. code-block:: ini
|
||
|
||
volume_driver = cinder.volume.drivers.netapp.common.NetAppDriver
|
||
netapp_storage_family = ontap_cluster
|
||
netapp_storage_protocol = nfs
|
||
|
||
- NetApp iSCSI direct driver for Data ONTAP operating in 7-Mode storage
|
||
controller in Grizzly (or earlier):
|
||
|
||
.. code-block:: ini
|
||
|
||
volume_driver = cinder.volume.drivers.netapp.iscsi.NetAppDirect7modeISCSIDriver
|
||
|
||
NetApp unified driver configuration:
|
||
|
||
.. code-block:: ini
|
||
|
||
volume_driver = cinder.volume.drivers.netapp.common.NetAppDriver
|
||
netapp_storage_family = ontap_7mode
|
||
netapp_storage_protocol = iscsi
|
||
|
||
- NetApp NFS direct driver for Data ONTAP operating in 7-Mode storage
|
||
controller in Grizzly (or earlier):
|
||
|
||
.. code-block:: ini
|
||
|
||
volume_driver = cinder.volume.drivers.netapp.nfs.NetAppDirect7modeNfsDriver
|
||
|
||
NetApp unified driver configuration:
|
||
|
||
.. code-block:: ini
|
||
|
||
volume_driver = cinder.volume.drivers.netapp.common.NetAppDriver
|
||
netapp_storage_family = ontap_7mode
|
||
netapp_storage_protocol = nfs
|
||
|
||
Deprecated NetApp drivers
|
||
-------------------------
|
||
|
||
This section lists the NetApp drivers in earlier releases that are
|
||
deprecated in Havana.
|
||
|
||
- NetApp iSCSI driver for clustered Data ONTAP:
|
||
|
||
.. code-block:: ini
|
||
|
||
volume_driver = cinder.volume.drivers.netapp.iscsi.NetAppCmodeISCSIDriver
|
||
|
||
- NetApp NFS driver for clustered Data ONTAP:
|
||
|
||
.. code-block:: ini
|
||
|
||
volume_driver = cinder.volume.drivers.netapp.nfs.NetAppCmodeNfsDriver
|
||
|
||
- NetApp iSCSI driver for Data ONTAP operating in 7-Mode storage
|
||
controller:
|
||
|
||
.. code-block:: ini
|
||
|
||
volume_driver = cinder.volume.drivers.netapp.iscsi.NetAppISCSIDriver
|
||
|
||
- NetApp NFS driver for Data ONTAP operating in 7-Mode storage
|
||
controller:
|
||
|
||
.. code-block:: ini
|
||
|
||
volume_driver = cinder.volume.drivers.netapp.nfs.NetAppNFSDriver
|
||
|
||
.. note::
|
||
|
||
For support information on deprecated NetApp drivers in the Havana
|
||
release, visit the `NetApp OpenStack Deployment and Operations
|
||
Guide <http://netapp.github.io/openstack-deploy-ops-guide/>`__.
|