The Sphinx build was issuing hundreds of warning for duplicate labels. The reason for this was because all of the tables we had were named as .rst files. This would cause Sphinx to process them twice and it would think there were duplicated sections. There were two ways this could be handled: 1) Exclude the tables directory from the docs build. 2) Name the files as they should have always been so they weren't build twice. Given that option 1 just masked the problem, I am implementing this patch using option 2. So, all the tables we are including in our documentation have been named from .rst to .inc and the .. include:: directives that use them have also been updated to use the new file name. Change-Id: If395eb652f7e3b789bcbd5e6d6d05954c23d8d8a
319 lines
10 KiB
ReStructuredText
319 lines
10 KiB
ReStructuredText
=====================================
|
|
CoprHD FC, iSCSI, and ScaleIO drivers
|
|
=====================================
|
|
|
|
CoprHD is an open source software-defined storage controller and API platform.
|
|
It enables policy-based management and cloud automation of storage resources
|
|
for block, object and file storage providers.
|
|
For more details, see `CoprHD <http://coprhd.org/>`_.
|
|
|
|
EMC ViPR Controller is the commercial offering of CoprHD. These same volume
|
|
drivers can also be considered as EMC ViPR Controller Block Storage drivers.
|
|
|
|
|
|
System requirements
|
|
~~~~~~~~~~~~~~~~~~~
|
|
|
|
CoprHD version 3.0 is required. Refer to the CoprHD documentation for
|
|
installation and configuration instructions.
|
|
|
|
If you are using these drivers to integrate with EMC ViPR Controller, use
|
|
EMC ViPR Controller 3.0.
|
|
|
|
|
|
Supported operations
|
|
~~~~~~~~~~~~~~~~~~~~
|
|
|
|
The following operations are supported:
|
|
|
|
- Create, delete, attach, detach, retype, clone, and extend volumes.
|
|
- Create, list, and delete volume snapshots.
|
|
- Create a volume from a snapshot.
|
|
- Copy a volume to an image.
|
|
- Copy an image to a volume.
|
|
- Clone a volume.
|
|
- Extend a volume.
|
|
- Retype a volume.
|
|
- Get volume statistics.
|
|
- Create, delete, and update consistency groups.
|
|
- Create and delete consistency group snapshots.
|
|
|
|
|
|
Driver options
|
|
~~~~~~~~~~~~~~
|
|
|
|
The following table contains the configuration options specific to the
|
|
CoprHD volume driver.
|
|
|
|
.. include:: ../../tables/cinder-coprhd.inc
|
|
|
|
|
|
Preparation
|
|
~~~~~~~~~~~
|
|
|
|
This involves setting up the CoprHD environment first and then configuring
|
|
the CoprHD Block Storage driver.
|
|
|
|
CoprHD
|
|
------
|
|
|
|
The CoprHD environment must meet specific configuration requirements to
|
|
support the OpenStack Block Storage driver.
|
|
|
|
- CoprHD users must be assigned a Tenant Administrator role or a Project
|
|
Administrator role for the Project being used. CoprHD roles are configured
|
|
by CoprHD Security Administrators. Consult the CoprHD documentation for
|
|
details.
|
|
|
|
- A CorprHD system administrator must execute the following configurations
|
|
using the CoprHD UI, CoprHD API, or CoprHD CLI:
|
|
|
|
- Create CoprHD virtual array
|
|
- Create CoprHD virtual storage pool
|
|
- Virtual Array designated for iSCSI driver must have an IP network created
|
|
with appropriate IP storage ports
|
|
- Designated tenant for use
|
|
- Designated project for use
|
|
|
|
.. note:: Use each back end to manage one virtual array and one virtual
|
|
storage pool. However, the user can have multiple instances of
|
|
CoprHD Block Storage driver, sharing the same virtual array and virtual
|
|
storage pool.
|
|
|
|
- A typical CoprHD virtual storage pool will have the following values
|
|
specified:
|
|
|
|
- Storage Type: Block
|
|
- Provisioning Type: Thin
|
|
- Protocol: iSCSI/Fibre Channel(FC)/ScaleIO
|
|
- Multi-Volume Consistency: DISABLED OR ENABLED
|
|
- Maximum Native Snapshots: A value greater than 0 allows the OpenStack user
|
|
to take Snapshots
|
|
|
|
|
|
CoprHD drivers - Single back end
|
|
--------------------------------
|
|
|
|
**cinder.conf**
|
|
|
|
#. Modify ``/etc/cinder/cinder.conf`` by adding the following lines,
|
|
substituting values for your environment:
|
|
|
|
.. code-block:: ini
|
|
|
|
[coprhd-iscsi]
|
|
volume_driver = cinder.volume.drivers.coprhd.iscsi.EMCCoprHDISCSIDriver
|
|
volume_backend_name = coprhd-iscsi
|
|
coprhd_hostname = <CoprHD-Host-Name>
|
|
coprhd_port = 4443
|
|
coprhd_username = <username>
|
|
coprhd_password = <password>
|
|
coprhd_tenant = <CoprHD-Tenant-Name>
|
|
coprhd_project = <CoprHD-Project-Name>
|
|
coprhd_varray = <CoprHD-Virtual-Array-Name>
|
|
coprhd_emulate_snapshot = True or False, True if the CoprHD vpool has VMAX or VPLEX as the backing storage
|
|
|
|
#. If you use the ScaleIO back end, add the following lines:
|
|
|
|
.. code-block:: ini
|
|
|
|
coprhd_scaleio_rest_gateway_host = <IP or FQDN>
|
|
coprhd_scaleio_rest_gateway_port = 443
|
|
coprhd_scaleio_rest_server_username = <username>
|
|
coprhd_scaleio_rest_server_password = <password>
|
|
scaleio_verify_server_certificate = True or False
|
|
scaleio_server_certificate_path = <path-of-certificate-for-validation>
|
|
|
|
#. Specify the driver using the ``enabled_backends`` parameter::
|
|
|
|
enabled_backends = coprhd-iscsi
|
|
|
|
.. note:: To utilize the Fibre Channel driver, replace the
|
|
``volume_driver`` line above with::
|
|
|
|
volume_driver = cinder.volume.drivers.coprhd.fc.EMCCoprHDFCDriver
|
|
|
|
.. note:: To utilize the ScaleIO driver, replace the ``volume_driver`` line
|
|
above with::
|
|
|
|
volume_driver = cinder.volume.drivers.coprhd.fc.EMCCoprHDScaleIODriver
|
|
|
|
.. note:: Set ``coprhd_emulate_snapshot`` to True if the CoprHD vpool has
|
|
VMAX or VPLEX as the back-end storage. For these type of back-end
|
|
storages, when a user tries to create a snapshot, an actual volume
|
|
gets created in the back end.
|
|
|
|
#. Modify the ``rpc_response_timeout`` value in ``/etc/cinder/cinder.conf`` to
|
|
at least 5 minutes. If this entry does not already exist within the
|
|
``cinder.conf`` file, add it in the ``[DEFAULT]`` section:
|
|
|
|
.. code-block:: ini
|
|
|
|
[DEFAULT]
|
|
# ...
|
|
rpc_response_timeout = 300
|
|
|
|
#. Now, restart the ``cinder-volume`` service.
|
|
|
|
**Volume type creation and extra specs**
|
|
|
|
#. Create OpenStack volume types:
|
|
|
|
.. code-block:: console
|
|
|
|
$ openstack volume type create <typename>
|
|
|
|
#. Map the OpenStack volume type to the CoprHD virtual pool:
|
|
|
|
.. code-block:: console
|
|
|
|
$ openstack volume type set <typename> --property CoprHD:VPOOL=<CoprHD-PoolName>
|
|
|
|
#. Map the volume type created to appropriate back-end driver:
|
|
|
|
.. code-block:: console
|
|
|
|
$ openstack volume type set <typename> --property volume_backend_name=<VOLUME_BACKEND_DRIVER>
|
|
|
|
|
|
CoprHD drivers - Multiple back-ends
|
|
-----------------------------------
|
|
|
|
**cinder.conf**
|
|
|
|
#. Add or modify the following entries if you are planning to use multiple
|
|
back-end drivers:
|
|
|
|
.. code-block:: ini
|
|
|
|
enabled_backends = coprhddriver-iscsi,coprhddriver-fc,coprhddriver-scaleio
|
|
|
|
#. Add the following at the end of the file:
|
|
|
|
.. code-block:: ini
|
|
|
|
[coprhddriver-iscsi]
|
|
volume_driver = cinder.volume.drivers.coprhd.iscsi.EMCCoprHDISCSIDriver
|
|
volume_backend_name = EMCCoprHDISCSIDriver
|
|
coprhd_hostname = <CoprHD Host Name>
|
|
coprhd_port = 4443
|
|
coprhd_username = <username>
|
|
coprhd_password = <password>
|
|
coprhd_tenant = <CoprHD-Tenant-Name>
|
|
coprhd_project = <CoprHD-Project-Name>
|
|
coprhd_varray = <CoprHD-Virtual-Array-Name>
|
|
|
|
|
|
[coprhddriver-fc]
|
|
volume_driver = cinder.volume.drivers.coprhd.fc.EMCCoprHDFCDriver
|
|
volume_backend_name = EMCCoprHDFCDriver
|
|
coprhd_hostname = <CoprHD Host Name>
|
|
coprhd_port = 4443
|
|
coprhd_username = <username>
|
|
coprhd_password = <password>
|
|
coprhd_tenant = <CoprHD-Tenant-Name>
|
|
coprhd_project = <CoprHD-Project-Name>
|
|
coprhd_varray = <CoprHD-Virtual-Array-Name>
|
|
|
|
|
|
[coprhddriver-scaleio]
|
|
volume_driver = cinder.volume.drivers.coprhd.scaleio.EMCCoprHDScaleIODriver
|
|
volume_backend_name = EMCCoprHDScaleIODriver
|
|
coprhd_hostname = <CoprHD Host Name>
|
|
coprhd_port = 4443
|
|
coprhd_username = <username>
|
|
coprhd_password = <password>
|
|
coprhd_tenant = <CoprHD-Tenant-Name>
|
|
coprhd_project = <CoprHD-Project-Name>
|
|
coprhd_varray = <CoprHD-Virtual-Array-Name>
|
|
coprhd_scaleio_rest_gateway_host = <ScaleIO Rest Gateway>
|
|
coprhd_scaleio_rest_gateway_port = 443
|
|
coprhd_scaleio_rest_server_username = <rest gateway username>
|
|
coprhd_scaleio_rest_server_password = <rest gateway password>
|
|
scaleio_verify_server_certificate = True or False
|
|
scaleio_server_certificate_path = <certificate path>
|
|
|
|
|
|
#. Restart the ``cinder-volume`` service.
|
|
|
|
|
|
**Volume type creation and extra specs**
|
|
|
|
Setup the ``volume-types`` and ``volume-type`` to ``volume-backend``
|
|
association:
|
|
|
|
.. code-block:: console
|
|
|
|
$ openstack volume type create "CoprHD High Performance ISCSI"
|
|
$ openstack volume type set "CoprHD High Performance ISCSI" --property CoprHD:VPOOL="High Performance ISCSI"
|
|
$ openstack volume type set "CoprHD High Performance ISCSI" --property volume_backend_name= EMCCoprHDISCSIDriver
|
|
|
|
$ openstack volume type create "CoprHD High Performance FC"
|
|
$ openstack volume type set "CoprHD High Performance FC" --property CoprHD:VPOOL="High Performance FC"
|
|
$ openstack volume type set "CoprHD High Performance FC" --property volume_backend_name= EMCCoprHDFCDriver
|
|
|
|
$ openstack volume type create "CoprHD performance SIO"
|
|
$ openstack volume type set "CoprHD performance SIO" --property CoprHD:VPOOL="Scaled Perf"
|
|
$ openstack volume type set "CoprHD performance SIO" --property volume_backend_name= EMCCoprHDScaleIODriver
|
|
|
|
|
|
ISCSI driver notes
|
|
~~~~~~~~~~~~~~~~~~
|
|
|
|
* The compute host must be added to the CoprHD along with its ISCSI
|
|
initiator.
|
|
* The ISCSI initiator must be associated with IP network on the CoprHD.
|
|
|
|
|
|
FC driver notes
|
|
~~~~~~~~~~~~~~~
|
|
|
|
* The compute host must be attached to a VSAN or fabric discovered
|
|
by CoprHD.
|
|
* There is no need to perform any SAN zoning operations. CoprHD will perform
|
|
the necessary operations automatically as part of the provisioning process.
|
|
|
|
|
|
ScaleIO driver notes
|
|
~~~~~~~~~~~~~~~~~~~~
|
|
|
|
* Install the ScaleIO SDC on the compute host.
|
|
* The compute host must be added as the SDC to the ScaleIO MDS
|
|
using the below commands::
|
|
|
|
/opt/emc/scaleio/sdc/bin/drv_cfg --add_mdm --ip List of MDM IPs
|
|
(starting with primary MDM and separated by comma)
|
|
Example:
|
|
/opt/emc/scaleio/sdc/bin/drv_cfg --add_mdm --ip
|
|
10.247.78.45,10.247.78.46,10.247.78.47
|
|
|
|
This step has to be repeated whenever the SDC (compute host in this case)
|
|
is rebooted.
|
|
|
|
|
|
Consistency group configuration
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
To enable the support of consistency group and consistency group snapshot
|
|
operations, use a text editor to edit the file ``/etc/cinder/policy.json`` and
|
|
change the values of the below fields as specified. Upon editing the file,
|
|
restart the ``c-api`` service::
|
|
|
|
"consistencygroup:create" : "",
|
|
"consistencygroup:delete": "",
|
|
"consistencygroup:get": "",
|
|
"consistencygroup:get_all": "",
|
|
"consistencygroup:update": "",
|
|
"consistencygroup:create_cgsnapshot" : "",
|
|
"consistencygroup:delete_cgsnapshot": "",
|
|
"consistencygroup:get_cgsnapshot": "",
|
|
"consistencygroup:get_all_cgsnapshots": "",
|
|
|
|
|
|
Names of resources in back-end storage
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
All the resources like volume, consistency group, snapshot, and consistency
|
|
group snapshot will use the display name in OpenStack for naming in the
|
|
back-end storage.
|