Replication failback support is added based on active_backend_id in Kaminario K2 iSCSI and FC Cinder drivers. Use "cinder failover-host" command to switch between failover and failback based on active_backend_id. If active_backend_id is secondary array, "cinder failover-host" will trigger failback code. Below are the steps as part of failback: 1)Search "failed-over" sessions on secondary array. 2)Change state of "failed-over" sessions to "in-sync". This will reverse the replication direction from secondary to primary. 3)Create external snapshots and synced to primary array volumes 4)Change state of "in-sync" sessions on primary to "failed-over". 5)Change state of "failed-over" sessions to "in-sync". This will reverse the replication direction from primary to secondary. Also, updated releasenotes of bug #1608913 DocImpact Closes-Bug: #1615178 Co-Authored-By: Nikesh Mahalka<Nikesh.Mahalka.ctr@kaminario.com> Co-Authored-By: Sreedhar Varma<Sreedhar.Varma.ctr@kaminario.com> Co-Authored-By: Lakshman<Lakshmi.Narayana.ctr@kaminario.com> Co-Authored-By: Ido Benda<Ido.Benda@kaminario.com> Change-Id: I664516ab31f9d33e4d14cd8615a1e0da4dba15b6
5 lines
104 B
YAML
5 lines
104 B
YAML
---
|
|
fixes:
|
|
- Added missing replication failback support in Kaminario iSCSI and
|
|
FC Cinder drivers.
|