Update the devstack script to point to the correct PowerMax drivers and to leverage the new PowerMax tags in cinder.conf merged in https://review.openstack.org/#/c/620659. Will change the name of the git repo at a later date. Change-Id: I0139e1ffd04ac7eb33021cd276e5b27379da79d0
138 lines
4.4 KiB
Bash
138 lines
4.4 KiB
Bash
#!/bin/bash
|
|
|
|
# devstack/plugin.sh
|
|
# Setup PowerMax as backend for Devstack
|
|
|
|
function update_volume_type {
|
|
# Update volume types
|
|
for be in ${CINDER_ENABLED_BACKENDS//,/ }; do
|
|
be_name=${be##*:}
|
|
be_type=${be%%:*}
|
|
if [[ ${be_type} == "powermax" ]]; then
|
|
array="${be_name}_Array"
|
|
srp="${be_name}_SRP"
|
|
slo="None"
|
|
workload="None"
|
|
pool_name=${!srp}+${!array}
|
|
powermax_temp="${be_name}_WORKLOAD"
|
|
if [ -n "${!powermax_temp}" ]; then
|
|
workload="${be_name}_WORKLOAD"
|
|
pool_name=${!workload}+${pool_name}
|
|
else
|
|
pool_name=${workload}+${pool_name}
|
|
fi
|
|
powermax_temp="${be_name}_SLO"
|
|
if [ -n "${!powermax_temp}" ]; then
|
|
slo="${be_name}_SLO"
|
|
pool_name=${!slo}+${pool_name}
|
|
else
|
|
pool_name=${slo}+${pool_name}
|
|
fi
|
|
openstack volume type set --property pool_name="${pool_name}" \
|
|
${be_name}
|
|
fi
|
|
done
|
|
}
|
|
|
|
function configure_port_groups {
|
|
local be_name=$1
|
|
powermax_temp="${be_name}_PortGroup"
|
|
dell_emc_portGroups=0
|
|
for i in ${!POWERMAX*}; do
|
|
temp1=${i##${powermax_temp}}
|
|
if [[ "$temp1" == "$i" ]]; then
|
|
continue
|
|
fi
|
|
arrIN=(${temp1//_/ })
|
|
if [[ "${arrIN[0]}" -gt "$dell_emc_portGroups" ]]; then
|
|
dell_emc_portGroups=${arrIN[0]}
|
|
fi
|
|
done
|
|
pg_list="["
|
|
for (( m=1 ; m<=dell_emc_portGroups ; m++ )) ; do
|
|
powermax_temp="${be_name}_PortGroup${m}"
|
|
pg_list="${pg_list}${!powermax_temp}"
|
|
if (( m!=dell_emc_portGroups )) ; then
|
|
pg_list="${pg_list},"
|
|
fi
|
|
done
|
|
pg_list="${pg_list}]"
|
|
iniset ${CINDER_CONF} ${be_name} powermax_port_groups ${pg_list}
|
|
}
|
|
|
|
function configure_single_pool {
|
|
local be_name=$1
|
|
configure_port_groups ${be_name}
|
|
for val in "SSLVerify" "Array" "SRP" "RestPassword" "RestUserName"\
|
|
"RestServerPort" "RestServerIp" ; do
|
|
powermax_temp="${be_name}_${val}"
|
|
if [ -n "${!powermax_temp}" ]; then
|
|
if [[ "${val}" == "RestServerIp" ]]; then
|
|
iniset ${CINDER_CONF} ${be_name} san_ip ${!powermax_temp}
|
|
elif [[ "${val}" == "RestServerPort" ]]; then
|
|
iniset ${CINDER_CONF} ${be_name} san_rest_port ${!powermax_temp}
|
|
elif [[ "${val}" == "RestUserName" ]]; then
|
|
iniset ${CINDER_CONF} ${be_name} san_login ${!powermax_temp}
|
|
elif [[ "${val}" == "RestPassword" ]]; then
|
|
iniset ${CINDER_CONF} ${be_name} san_password ${!powermax_temp}
|
|
elif [[ "${val}" == "Array" ]]; then
|
|
iniset ${CINDER_CONF} ${be_name} powermax_array ${!powermax_temp}
|
|
elif [[ "${val}" == "SRP" ]]; then
|
|
iniset ${CINDER_CONF} ${be_name} powermax_srp ${!powermax_temp}
|
|
elif [[ "${val}" == "SSLVerify" ]]; then
|
|
if [[ "${!powermax_temp}" != "False" ]]; then
|
|
iniset ${CINDER_CONF} ${be_name} driver_ssl_cert_verify \
|
|
True
|
|
iniset ${CINDER_CONF} ${be_name} driver_ssl_cert_path \
|
|
${!powermax_temp}
|
|
fi
|
|
fi
|
|
fi
|
|
done
|
|
}
|
|
|
|
function configure_cinder_backend_powermax {
|
|
local be_name=$1
|
|
local emc_multi=${be_name%%_*}
|
|
|
|
configure_single_pool ${be_name}
|
|
|
|
storage_proto="${be_name}_StorageProtocol"
|
|
powermax_directory="cinder.volume.drivers.dell_emc.powermax."
|
|
if [[ "${!storage_proto}" == "iSCSI" ]]; then
|
|
iniset ${CINDER_CONF} ${be_name} volume_driver \
|
|
"${powermax_directory}iscsi.PowerMaxISCSIDriver"
|
|
fi
|
|
if [ "${!storage_proto}" = "FC" ]; then
|
|
iniset ${CINDER_CONF} ${be_name} volume_driver \
|
|
"${powermax_directory}fc.PowerMaxFCDriver"
|
|
fi
|
|
iniset ${CINDER_CONF} ${be_name} volume_backend_name ${be_name}
|
|
}
|
|
|
|
if [[ "$1" == "stack" && "$2" == "pre-install" ]]; then
|
|
# no-op
|
|
:
|
|
elif [[ "$1" == "stack" && "$2" == "install" ]]; then
|
|
# no-op
|
|
:
|
|
elif [[ "$1" == "stack" && "$2" == "post-config" ]]; then
|
|
# no-op
|
|
:
|
|
elif [[ "$1" == "stack" && "$2" == "extra" ]]; then
|
|
update_volume_type
|
|
elif [[ "$1" == "stack" && "$2" == "post-extra" ]]; then
|
|
# no-op
|
|
:
|
|
fi
|
|
|
|
if [[ "$1" == "unstack" ]]; then
|
|
# no-op
|
|
:
|
|
fi
|
|
|
|
if [[ "$1" == "clean" ]]; then
|
|
# no-op
|
|
:
|
|
fi
|